Evidence map›Paper›PMID 38116822›Full record

ArticleMedical physics2024

The effect of frequency (64-498 MHz) on specific absorption rate adjacent to metallic orthopedic screws in MRI: A numerical simulation study.

Paul Jacobs, Andrew J Fagan

Open access · hybridAbstract read
In one paragraph

Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Reduction of radiofrequency induced implant heating via flexible metasurface shielding at 7 T.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2025
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Paul JacobsDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Andrew J FaganDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Mayo Clinic · US

Funding

Mayo Clinic Center for Translational Science ActivitiesUL1TR000135 · NCATS · MAYO CLINIC ROCHESTER · PI KHOSLA, SUNDEEP · 2012 to 2015
$41.2M
Yale-Mayo FDA Center for Excellence in Regulatory Science and InnovationU01FD005938 · FDA · YALE UNIVERSITY · PI Joseph Solomon Ross · 2016 to 2026
$25.4M
Post-baccalaureate Training in Biomedical ResearchR25GM075148 · NIGMS · MAYO CLINIC ROCHESTER · PI LUJAN, LUIS, MAHER, LOUIS JAMES · 2006 to 2024
$6.1M
FDA HHS U01 FD005938NCATS NIH HHS UL1 TR000135NIGMS NIH HHS R25 GM075148NIH HHS 5 R25 GM075148
6 · The paper itself

Abstract

backgroundThe imaging of patients with implanted electrically-conductive devices via magnetic resonance imaging at ultra-high fields is hampered by uncertainties relating to the potential for inducing tissue heating adjacent to the implant due to coupling of energy from the incident electromagnetic field into the implant. Existing data in the peer-reviewed literature of comparisons across field strengths of tissue heating and its surrogate, the specific absorption rate (SAR), is scarce and contradictory, leading to further doubts pertaining to the safety of imaging patients with such devices. PURPOSE: The radiofrequency-induced SAR adjacent to orthopedic screws of varying length and at frequencies of 64 to 498 MHz was investigated via full-wave electromagnetic simulations, to provide an accurate comparison of SAR across MRI field strengths.

methodsDipole antennas were used for RF transmission to achieve a uniform electric field tangential to the screws located 120 mm above the antenna midpoints, embedded in a bone-mimicking material. The input power to the antennas was constrained to achieve the following targets without the screw present: (i) E = 100 V/m, (ii) B

resultsThe peak SAR, occurring at the resonant screw length, substantially increased as the frequency decreased when the input power to the dipole antenna was constrained to achieve constant electric field in background tissue at the screws' locations. A similar pattern was observed when constraining input power to achieve constant B

conclusionsThe study design allowed for a direct comparison to be performed of SAR across frequencies and implant lengths without the confounding effect of variable incident electric field. Lower frequencies produced substantially larger SAR values for implants approaching the resonant length for the worst-case uniform incident electric field along the screws' length. The data may inform risk-benefit assessments for imaging patients with orthopedic implants at the new clinical field strength of 7 Tesla.

Indexed as

Electromagnetic FieldsRadio WavesComputer SimulationHumansMagnetic Resonance ImagingPhantoms, ImagingProstheses and ImplantsMR safetyRF-induced heatingSARultra-high field

Identifiers

PMID38116822
PMCPMC10922637
OpenAlexW4389998624

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.