Evidence map›Paper›PMID 38116087›Full record

ArticleNational science review2024

High-timing-precision detection of single X-ray photons by superconducting nanowires.

Shuya Guo, Jingrou Tan, Hengbin Zhang, Jinguang Wang, Tianhao Ji, Labao Zhang, Xiaolong Hu, Jian Chen, Jun Xie, Kai Zou and 10 more

Abstract read
In one paragraph

Article in National science review, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

20 authors.

Shuya GuoResearch Institute of Superconductor Electronics, Nanjing University, Nanjing 210093, China.
Jingrou TanResearch Institute of Superconductor Electronics, Nanjing University, Nanjing 210093, China.
Hengbin ZhangQian Xuesen Laboratory of Space Technology, Beijing 100094, China.
Jinguang WangBeijing National Laboratory of Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China.
Tianhao JiResearch Institute of Superconductor Electronics, Nanjing University, Nanjing 210093, China.
Labao ZhangResearch Institute of Superconductor Electronics, Nanjing University, Nanjing 210093, China.ORCID https://orcid.org/0000-0002-6510-0171
Xiaolong HuSchool of Precision Instrument and Optoelectronic Engineering, Tianjin University, Tianjin 300072, China.
Jian ChenResearch Institute of Superconductor Electronics, Nanjing University, Nanjing 210093, China.
Jun XieQian Xuesen Laboratory of Space Technology, Beijing 100094, China.
Kai ZouSchool of Precision Instrument and Optoelectronic Engineering, Tianjin University, Tianjin 300072, China.
Yun MengSchool of Precision Instrument and Optoelectronic Engineering, Tianjin University, Tianjin 300072, China.
Xiaomin BeiQian Xuesen Laboratory of Space Technology, Beijing 100094, China.
Ling-An WuBeijing National Laboratory of Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China.
Qi ChenResearch Institute of Superconductor Electronics, Nanjing University, Nanjing 210093, China.
Hao WangResearch Institute of Superconductor Electronics, Nanjing University, Nanjing 210093, China.
Xuecou TuResearch Institute of Superconductor Electronics, Nanjing University, Nanjing 210093, China.
Xiaoqing JiaResearch Institute of Superconductor Electronics, Nanjing University, Nanjing 210093, China.
Qing-Yuan ZhaoResearch Institute of Superconductor Electronics, Nanjing University, Nanjing 210093, China.
Lin KangResearch Institute of Superconductor Electronics, Nanjing University, Nanjing 210093, China.
Peiheng WuResearch Institute of Superconductor Electronics, Nanjing University, Nanjing 210093, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Precisely acquiring the timing information of individual X-ray photons is important in both fundamental research and practical applications. The timing precision of commonly used X-ray single-photon detectors remains in the range of one hundred picoseconds to microseconds. In this work, we report on high-timing-precision detection of single X-ray photons through the fast transition to the normal state from the superconductive state of superconducting nanowires. We successfully demonstrate a free-running X-ray single-photon detector with a timing resolution of 20.1 ps made of 100-nm-thick niobium nitride film with an active area of 50

Indexed as

pulsar X-ray navigationsingle-photon detectionsuperconductortiming precisionultrafast phenomenon

Identifiers

PMID38116087
PMCPMC10727846

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.