Evidence map›Paper›PMID 38114969›Full record

ArticleBMC surgery2023

Computed tomography-based patient-specific cutting guides used for positioning of the femoral component of implants during unicompartmental knee arthroplasty: a cadaver study.

Junfeng Cai, Min Ma, Wen Zeng, Shuling Luo, Feng Yuan, Feng Yin

Abstract read
In one paragraph

Article in BMC surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Junfeng Cai *Department of joint surgery, Shanghai east hospital, Tongji university, school of medicine, Shanghai, 200120, China.
Min Ma *Department of joint surgery, Shanghai east hospital, Tongji university, school of medicine, Shanghai, 200120, China.
Wen ZengDepartment of joint surgery, Shanghai east hospital, Tongji university, school of medicine, Shanghai, 200120, China.
Shuling LuoDepartment of joint surgery, Shanghai east hospital, Tongji university, school of medicine, Shanghai, 200120, China.
Feng YuanDepartment of joint surgery, Shanghai east hospital, Tongji university, school of medicine, Shanghai, 200120, China. 13818811863@163.com.
Feng YinDepartment of joint surgery, Shanghai east hospital, Tongji university, school of medicine, Shanghai, 200120, China. yinfengdf@163.com.

Funding

Pudong Health and Family Planning Commission of Shanghai PWZzk2017-25Shanghai Municipal Committee of Science and Technology 14411967300
6 · The paper itself

Abstract

backgroundTo investigate whether patient-specific instrumentation (PSI) improves the femoral component positioning of implants during unicompartmental knee arthroplasty (UKA) using cadaver bone models.

methodsFifty adult cadaveric femoral bone specimens collected from February 2016-2018, were randomized to receive medial UKA with a PSI guide (n = 25) or conventional instrumentation (CI) (n = 25). Standard anteroposterior and lateral view radiographs were obtained postoperatively to assess the coronal and sagittal positioning of the femoral prostheses, respectively. The osteotomy time was recorded to assess the convenience of PSI in guiding osteotomy.

resultsOsteotomy time significantly shortened in the PSI group (3.12 ± 0.65 versus 4.33 ± 0.73 min, p < 0.001). There was a significant difference in the postoperative coronal alignment of the femoral component between the PSI and CI groups (varus/valgus angle: 1.43 ± 0.93° vs. 2.65 ± 1.50°, p = 0.001). The prevalence of outliers in coronal alignment was lower in the PSI than the CI group (2/25, 8% vs. 9/25, 36%). Sagittal posterior slope angle of the femoral component was significantly different between the two groups (8.80 ± 0.65° and 6.29 ± 1.88° in the CI and PSI groups, respectively, p < 0.001). The malalignment rate of the femoral component in the sagittal plane was 60% in the CI group, whereas no positioning deviation was observed in the PSI group.

conclusionThis study used a cadaver model to support the fact that CT-based PSI shows an advantage over CI in optimizing implant positioning for UKAs.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeCadaverFemurHumansKnee JointProstheses and ImplantsTibiaTomography, X-Ray ComputedComponent alignmentFemoral cutting guidesPatient-specific instrumentationUnicompartmental knee arthroplasty

Identifiers

PMID38114969
PMCPMC10729329

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.