Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: An in vitro study.

Priscila Ceolin Meneghetti, Junying Li, Paulo Sérgio Borella, Gustavo Mendonça, Luiz Henrique Burnett

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
5.4field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Impact of scanning errors on the trueness of digital implant impressions.International journal of implant dentistry · 2026
    Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Priscila Ceolin MeneghettiSchool of Health and Life Sciences, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil.ORCID 0000-0001-8421-3131
Junying LiDepartment of Biological and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Michigan, United States of America.
Paulo Sérgio BorellaDepartment of General Practice, Virginia Commonwealth University School of Dentistry, Richmond, Virginia, United States of America.
Gustavo MendonçaDepartment of General Practice, Virginia Commonwealth University School of Dentistry, Richmond, Virginia, United States of America.ORCID 0000-0003-2290-4046
Luiz Henrique BurnettSchool of Health and Life Sciences, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil.ORCID 0000-0002-9080-7785
University of Michigan · USVirginia Commonwealth University · USPontifícia Universidade Católica do Rio Grande do Sul · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to compare the accuracy of full-arch digital implant impressions using seven different scanbodies and four intraoral scanners. A 3D-printed maxillary model with six implants and their respective multi-unit abutments was used for this study. Seven scanbodies (SB1, SB2, SB3, SB4, SB5, SB6, and SB7) and four intraoral scanners (Primescan®, Omnican®, Trios 3®, and Trios 4®) were assessed. Each combination group was scanned ten times and a dental lab scanner (D2000, 3Shape) was used as a reference. All scans were exported as STL files, imported into Convince software (3Shape) for alignment, and later into Blender software, where their 3D positions were analyzed using a Python script. The 3D deviation, angular deviation, and linear distance between implants #3 and #14 were also measured. Accuracy was measured in terms of "trueness" (scanbody 3D deviation between intraoral scan and desktop scan). Kruskal-Wallis followed by the Bonferroni correction was used to analyze the data (⍺ = .05). The study found statistically significant differences in digital impression accuracy among the scanners and scanbodies (p<0.001). When comparing different intraoral scanners, the Primescan system showed the smallest 3D deviation (median 110.59 μm) and differed statistically from the others, while Trios 4 (median 122.35 μm) and Trios 3 (median 130.62 μm) did not differ from each other (p = .284). No differences were found in the linear distance between implants #3 and #14 between Trios 4, Primescan, and Trios 3 systems. When comparing different scanbodies, the lowest median values for 3D deviation were obtained by SB2 (72.27μm) and SB7 (93.31μm), and they did not differ from each other (p = .116). The implant scanbody and intraoral scanner influenced the accuracy of digital impressions on completely edentulous arches.

Indexed as

Dental ImplantsMouth, EdentulousComputer-Aided DesignDental ArchDental Impression TechniqueHumansImaging, Three-DimensionalModels, DentalProstheses and ImplantsDental Implants

Identifiers

PMID38113200
PMCPMC10729975
OpenAlexW4389945525

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.