ArticlePloS one2023
Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: An in vitro study.
Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 21 citations in OpenAlex.
- Dimensional Stability of Polymer and Titanium Implant Scan Bodies After Repeated Steam Sterilization: A High-Resolution 3D Metrological In Vitro Study.Journal of functional biomaterials · 2026Article
- Impact of scanning errors on the trueness of digital implant impressions.International journal of implant dentistry · 2026Article
- PEEK Intraoral Scan Bodies-A Scoping Review.Dentistry journal · 2026Review
- Influence of camera position, implant angulation and implant reference on the accuracy of complete arch implant recordings with photogrammetry.The journal of advanced prosthodontics · 2025Article
- Effects of inter-implant tooth loss and scan body material on digital impression accuracy: an in vitro study.BMC oral health · 2025Article
- The Effects of Scan Body Geometry on the Precision and the Trueness of Implant Impressions Using Intraoral Scanners: A Systematic Review.Dentistry journal · 2025Review
- The influence of the superimposition procedure and type of intraoral impression on the superimposition accuracy of CBCT scans with dental impressions in implant planning: an in-vitro study.International journal of implant dentistry · 2025Article
- Article
- Accuracy of intraoral scanners for full-arch implant scanning in the Maxilla using horizontal scanbody.PloS one · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study aimed to compare the accuracy of full-arch digital implant impressions using seven different scanbodies and four intraoral scanners. A 3D-printed maxillary model with six implants and their respective multi-unit abutments was used for this study. Seven scanbodies (SB1, SB2, SB3, SB4, SB5, SB6, and SB7) and four intraoral scanners (Primescan®, Omnican®, Trios 3®, and Trios 4®) were assessed. Each combination group was scanned ten times and a dental lab scanner (D2000, 3Shape) was used as a reference. All scans were exported as STL files, imported into Convince software (3Shape) for alignment, and later into Blender software, where their 3D positions were analyzed using a Python script. The 3D deviation, angular deviation, and linear distance between implants #3 and #14 were also measured. Accuracy was measured in terms of "trueness" (scanbody 3D deviation between intraoral scan and desktop scan). Kruskal-Wallis followed by the Bonferroni correction was used to analyze the data (⍺ = .05). The study found statistically significant differences in digital impression accuracy among the scanners and scanbodies (p<0.001). When comparing different intraoral scanners, the Primescan system showed the smallest 3D deviation (median 110.59 μm) and differed statistically from the others, while Trios 4 (median 122.35 μm) and Trios 3 (median 130.62 μm) did not differ from each other (p = .284). No differences were found in the linear distance between implants #3 and #14 between Trios 4, Primescan, and Trios 3 systems. When comparing different scanbodies, the lowest median values for 3D deviation were obtained by SB2 (72.27μm) and SB7 (93.31μm), and they did not differ from each other (p = .116). The implant scanbody and intraoral scanner influenced the accuracy of digital impressions on completely edentulous arches.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.