SynthesisPloS one2023
Diagnostic accuracy of endocytoscopy via artificial intelligence in colorectal lesions: A systematic review and meta‑analysis.
Synthesis in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 7 citations in OpenAlex.
- Development of prediction models for perioperative opioid needs in laparoscopic cholecystectomy patients: A machine-learning approach.Surgery open science · 2026Article
- Development and validation of a novel scoring scale for colonic endocytoscopy staining quality.Scientific reports · 2026Article
- Optical Imaging Technologies and Clinical Applications in Gastrointestinal Endoscopy.Diagnostics (Basel, Switzerland) · 2025Review
- Texture and Color Enhancement Imaging-Assisted Endocytoscopy Improves Characterization of Gastric Precancerous Conditions: A Set of Interesting Comparative Images.Diagnostics (Basel, Switzerland) · 2025Article
- Artificial Intelligence and Early Detection of Breast, Lung, and Colon Cancer: A Narrative Review.Cureus · 2025Review
- Emerging Technologies in Endoscopy for Gastrointestinal Neoplasms: A Comprehensive Overview.Cureus · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundEndocytoscopy (EC) is a nuclei and micro-vessels visualization in real-time and can facilitate "optical biopsy" and "virtual histology" of colorectal lesions. This study aimed to investigate the significance of employing artificial intelligence (AI) in the field of endoscopy, specifically in diagnosing colorectal lesions. The research was conducted under the supervision of experienced professionals and trainees.
methodsEMBASE, PubMed, Cochrane Library, Web of Science, Chinese National Knowledge Infrastructure (CNKI) database, and other potential databases were surveyed for articles related to the EC with AI published before September 2023. RevMan (5.40), Stata (14.0), and R software (4.1.0) were used for statistical assessment. Studies that measured the accuracy of EC using AI for colorectal lesions were included. Two authors independently assessed the selected studies and their extracted data. This included information such as the country, literature, total study population, study design, characteristics of the fundamental study and control groups, sensitivity, number of samples, assay methodology, specificity, true positives or negatives, and false positives or negatives. The diagnostic accuracy of EC by AI was determined by a bivariate random-effects model, avoiding a high heterogeneity effect. The ANOVA model was employed to determine the more effective approach.
resultsA total of 223 studies were reviewed; 8 articles were selected that included 2984 patients (4241 lesions) for systematic review and meta-analysis. AI assessed 4069 lesions; experts diagnosed 3165 and 5014 by trainees. AI demonstrated high accuracy, sensitivity, and specificity levels in detecting colorectal lesions, with values of 0.93 (95% CI: 0.90, 0.95) and 0.94 (95% CI: 0.73, 0.99). Expert diagnosis was 0.90 (95% CI: 0.85, 0.94), 0.87 (95% CI: 0.78, 0.93), and trainee diagnosis was 0.74 (95% CI: 0.67, 0.79), 0.72 (95% CI: 0.62, 0.80). With the EC by AI, the AUC from SROC was 0.95 (95% CI: 0.93, 0.97), therefore classified as excellent category, expert showed 0.95 (95% CI: 0.93, 0.97), and the trainee had 0.79 (95% CI: 0.75, 0.82). The superior index from the ANOVA model was 4.00 (1.15,5.00), 2.00 (1.15,5.00), and 0.20 (0.20,0.20), respectively. The examiners conducted meta-regression and subgroup analyses to evaluate the presence of heterogeneity. The findings of these investigations suggest that the utilization of NBI technology was correlated with variability in sensitivity and specificity. There was a lack of solid evidence indicating the presence of publishing bias.
conclusionsThe present findings indicate that using AI in EC can potentially enhance the efficiency of diagnosing colorectal abnormalities. As a valuable instrument, it can enhance prognostic outcomes in ordinary EC procedures, exhibiting superior diagnostic accuracy compared to trainee-level endoscopists and demonstrating comparability to expert endoscopists. The research is subject to certain constraints, namely a limited number of clinical investigations and variations in the methodologies used for identification. Consequently, it is imperative to conduct comprehensive and extensive research to enhance the precision of diagnostic procedures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.