ArticleTranslational vision science & technology2023
Establishing Fully-Automated Fundus-Controlled Dark Adaptometry: A Validation and Retest-Reliability Study.
Article in Translational vision science & technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07515521 (Enhanced Vision and Imaging Tests for Enabling Treatment Trials in Early and Intermediate AMD), which is not on this map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Enhanced Vision and Imaging Tests for Enabling Treatment Trials in Early and Intermediate AMD
Who cites it
8 citing papers in PubMed, 12 citations in OpenAlex.
- Parafoveal Dark Adaptation in Early and Intermediate Age-Related Macular Degeneration.Investigative ophthalmology & visual science · 2026Article
- Introducing Christine A. Curcio and Cynthia Owsley, the 2025 Recipients of the Proctor Medal.Investigative ophthalmology & visual science · 2026Article
- Drusen-specific dark adaptation profiles in intermediate age-related macular degeneration.International journal of retina and vitreous · 2026Article
- Measurement Reliability and Functional Validity of Bruch's Membrane Calcification in Pseudoxanthoma Elasticum: PROPXE Study Report 2.Investigative ophthalmology & visual science · 2025Article
- Dark Adaptometry as a Diagnostic Tool in Retinal Diseases: Mechanisms and Clinical Utility.Journal of clinical medicine · 2025Review
- Topography of Slowed Dark Adaptation in Pseudoxanthoma Elasticum: PROPXE Study Report 1.Investigative ophthalmology & visual science · 2025Observational
- Article
- Evaluation of Retinal Structure and Visual Function in Blue Cone Monochromacy to Develop Clinical Endpoints for L-opsin Gene Therapy.International journal of molecular sciences · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
Abstract
Purpose: The purpose of this study was to establish and validate a novel fundus-controlled dark-adaptometry method. Methods: We developed a custom dark-adaptometry software for the S-MAIA device using the open-perimetry-interface. In the validation-substudy, participants underwent dark-adaptometry testing with a comparator device (MonCvONE, 59% rhodopsin bleach, cyan and red stimuli centered at 2 degrees, 4 degrees, and 6 degrees eccentricity). Following a brief break (approximately 5 minutes), the participants were bleached again and underwent dark-adaptometry testing with the S-MAIA device (same loci). In the retest reliability-substudy, participants were tested twice with the S-MAIA device (same loci as above). Nonlinear curve fitting was applied to extract dark-adaptation curve parameters. Validity and repeatability were summarized in terms of the mean bias and 95% limits of agreement (LoAs). Results: In the validation-substudy (N = 20 participants, median age interquartile range [IQR] 31.5 years [IQR = 25.8, 62.0]), measures of rod-mediated dark-adaptation showed little to no between method differences for the cone-rod-break-time (bias 95% confidence interval [95% CI] of +0.1 minutes [95% CI = -0.6 to 0.8]), rod-intercept-time (-0.23 minutes [95% CI = -1.38 to 0.93]), and S2 slope (-0.01 LogUnits/minutes [95% CI = -0.02 to -0.01]). In the retest reliability-substudy (N = 10 participants, 32.0 years [95% CI = 27.0, 57.5]), the corresponding LoAs were (cone-rod-break-time) -3.94 to 2.78 minutes, (rod-intercept-time) -4.55 to 3.11 minutes, and (S2 slope [rate-limited component of rod recovery]) -0.03 to 0.03 LogUnits/minutes. The LoAs for the steady-state cone and rod thresholds were -0.28 to 0.33 LogUnits and -0.34 to 0.28 LogUnits. Conclusions: The devised fundus-controlled dark-adaptometry method yields valid and reliable results. Translational Relevance: Fundus-controlled dark-adaptometry solves the critical need for localized testing of the visual cycle and retinoid transfer in eyes with unstable fixation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.