Evidence map›Paper›PMID 38110736›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Impact of support instruments in medial closed-wedge distal femoral osteotomy: a finite element analysis.

Umito Kuwashima, Masafumi Itoh, Junya Itou, Ken Okazaki

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Umito KuwashimaDepartment of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666, Japan. kuwashima.umito@twmu.ac.jp.ORCID http://orcid.org/0000-0002-1943-5026
Masafumi ItohDepartment of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Junya ItouDepartment of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Ken OkazakiDepartment of Orthopaedic Surgery, Tokyo Women's Medical University, 8-1 Kawada-Cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
Tokyo Women's Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionMedial closed-wedge distal femoral osteotomy (MCWDFO) is a valuable treatment approach for lateral knee osteoarthritis with femoral valgus deformity. Improved results have been reported with the upgrade of surgical techniques and locking plates. However, the risk of nonunion and loss of correction increases in cases of lateral hinge fractures. This study aimed to evaluate the mechanical impact of hinge fractures and support instruments in MCWDFO using finite element analysis (FEA). MATERIALS AND

methodsFive femur models were developed using Mechanical Finder 11.0 FEA software. We simulated the following models: only a medial locking plate (MLP) (group A); an MLP with a lateral support screw (group B); and an MLP with a lateral support plate (group C). The equivalent stress around the hinge was evaluated and the percentage of the plastic deformation zone was calculated for the hinge area in the no-hinge fracture model. The equivalent stress of the MLP and the degree of displacement were calculated using the hinge fracture model.

resultsThe percentages of the plastic deformation zone in groups A, B, and C were 18.0 ± 11.7%, 3.3 ± 2.4%, and 2.3 ± 2.8%, respectively. The percentages tended to be lower in groups B and C than in group A. In the hinge fracture model, the mean equivalent stress of the MLP in group C was significantly less than that in group A. In terms of the mean degree of displacement, group A showed more than 1 mm of displacement, which was significantly larger than that of the other groups.

conclusionThe support instruments provided stability to the hinge site and reduced the equivalent stress of the main plate in the MCWDFO with hinge fractures. No significant difference was observed between the two instruments in terms of stability.

Indexed as

Fractures, BoneOsteoarthritis, KneeFemurFinite Element AnalysisHumansKnee JointOsteotomyTibiaFinite element analysisHinge fractureMedial closed-wedge distal femoral osteotomySupport instrumentValgus alignment

Identifiers

PMID38110736
OpenAlexW4389913886

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.