Evidence map›Paper›PMID 38110729›Full record

ArticleEuropean radiology experimental2023

Comparison of ultrahigh and standard resolution photon-counting CT angiography of the femoral arteries in a continuously perfused in vitro model.

Philipp Gruschwitz, Viktor Hartung, Süleyman Ergün, Dominik Peter, Sven Lichthardt, Henner Huflage, Robin Hendel, Pauline Pannenbecker, Anne Marie Augustin, Andreas Steven Kunz and 3 more

Open access · goldAbstract read
In one paragraph

Article in European radiology experimental, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.2field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 2 institutions in 1 country.

Philipp GruschwitzDepartment of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany. Gruschwitz_P@ukw.de.ORCID 0000-0002-2565-8111
Viktor HartungDepartment of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany.
Süleyman ErgünInstitute of Anatomy and Cell Biology, University of Würzburg, Würzburg, Germany.
Dominik PeterDepartment of General, Visceral, Transplant, Vascular, and Pediatric Surgery, University Hospital of Würzburg, Würzburg, Germany.
Sven LichthardtDepartment of General, Visceral, Transplant, Vascular, and Pediatric Surgery, University Hospital of Würzburg, Würzburg, Germany.
Henner HuflageDepartment of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany.
Robin HendelDepartment of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany.
Pauline PannenbeckerDepartment of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany.
Anne Marie AugustinDepartment of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany.
Andreas Steven KunzDepartment of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany.
Philipp FeldleDepartment of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany.
Thorsten Alexander BleyDepartment of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany.
Jan-Peter GrunzDepartment of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany.
Universitätsklinikum Würzburg · DEUniversity of Würzburg · DE

Funding

Interdisziplinäres Zentrum für Klinische Forschung, Universitätsklinikum Würzburg Z-02CSP/18Interdisziplinäres Zentrum für Klinische Forschung, Universitätsklinikum Würzburg Z-3BC/02Julius-Maximilians-Universität Würzburg Publication Fund
6 · The paper itself

Abstract

backgroundWith the emergence of photon-counting CT, ultrahigh-resolution (UHR) imaging can be performed without dose penalty. This study aims to directly compare the image quality of UHR and standard resolution (SR) scan mode in femoral artery angiographies.

methodsAfter establishing continuous extracorporeal perfusion in four fresh-frozen cadaveric specimens, photon-counting CT angiographies were performed with a radiation dose of 5 mGy and tube voltage of 120 kV in both SR and UHR mode. Images were reconstructed with dedicated convolution kernels (soft: Body-vascular (Bv)48; sharp: Bv60; ultrasharp: Bv76). Six radiologists evaluated the image quality by means of a pairwise forced-choice comparison tool. Kendall's concordance coefficient (W) was calculated to quantify interrater agreement. Image quality was further assessed by measuring intraluminal attenuation and image noise as well as by calculating signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR).

resultsUHR yielded lower noise than SR for identical reconstructions with kernels ≥ Bv60 (p < 0.001). UHR scans exhibited lower intraluminal attenuation compared to SR (Bv60: 406.4 ± 25.1 versus 418.1 ± 30.1 HU; p < 0.001). Irrespective of scan mode, SNR and CNR decreased while noise increased with sharper kernels but UHR scans were objectively superior to SR nonetheless (Bv60: SNR 25.9 ± 6.4 versus 20.9 ± 5.3; CNR 22.7 ± 5.8 versus 18.4 ± 4.8; p < 0.001). Notably, UHR scans were preferred in subjective assessment when images were reconstructed with the ultrasharp Bv76 kernel, whereas SR was rated superior for Bv60. Interrater agreement was high (W = 0.935).

conclusionsCombinations of UHR scan mode and ultrasharp convolution kernel are able to exploit the full image quality potential in photon-counting CT angiography of the femoral arteries. RELEVANCE STATEMENT: The UHR scan mode offers improved image quality and may increase diagnostic accuracy in CT angiography of the peripheral arterial runoff when optimized reconstruction parameters are chosen. KEY POINTS: • UHR photon-counting CT improves image quality in combination with ultrasharp convolution kernels. • UHR datasets display lower image noise compared with identically reconstructed standard resolution scans. • Scans in UHR mode show decreased intraluminal attenuation compared with standard resolution imaging.

Indexed as

Computed Tomography AngiographyFemoral ArteryAngiographyHumansPhantoms, ImagingTomography, X-Ray ComputedCT angiographyFemoral arteriesPhoton-counting computed tomography (CT)Small pixel effectUltrahigh resolution

Identifiers

PMID38110729
PMCPMC10728414
OpenAlexW4389914527

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.