Evidence map›Paper›PMID 38108926›Full record

ArticleJournal of experimental orthopaedics2023

The quest for optimal femoral torsion angle measurements: a comparative advanced 3D study defining the femoral neck axis.

Bert Van Fraeyenhove, Jeroen C F Verhaegen, Jonas Grammens, Gino Mestach, Emmanuel Audenaert, Annemieke Van Haver, Peter Verdonk

Open access · goldAbstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Influence of limb position on femoral neck anteversion angle measurement during computed tomography imaging.Asia-Pacific journal of sports medicine, arthroscopy, rehabilitation and technology · 2025
    Article
  5. The rise of hip research in theJournal of experimental orthopaedics · 2025
    Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Bert Van FraeyenhoveUniversitair Ziekenhuis Antwerpen, Antwerp, Belgium. bertvanfraeyenhove@gmail.com.ORCID http://orcid.org/0000-0002-3864-5782
Jeroen C F VerhaegenUniversitair Ziekenhuis Antwerpen, Antwerp, Belgium.
Jonas GrammensUniversity of Antwerp, Antwerp, Belgium.
Gino MestachUniversitair Ziekenhuis Antwerpen, Antwerp, Belgium.
Emmanuel AudenaertUniversitair Ziekenhuis Gent, Ghent, Belgium.
Annemieke Van HaverAZ Monica, Antwerp, Belgium.
Peter VerdonkOrthoca, Kielsevest 14, Antwerp, 2018, Belgium.
Universitair Ziekenhuis Leuven · BEProvince of Antwerp · BEGhent University Hospital · BEUniversity of Antwerp · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThere is high variability in femoral torsion, measured on two-dimensional (2D) computed tomography (CT) scans. The aim of this study was to find a reliable three-dimensional (3D) femoral torsion measurement method, assess the influence of CAM deformity on femoral torsion measurement, and to promote awareness for the used measurement method.

methods3D models of 102 dry femur specimens were divided into a CAM and non-CAM group. Femoral torsion was measured by one 2D-CT method described by Murphy et al. (method 0) and five 3D methods. The 3D methods differed in strategies to define the femoral neck axis. Method 1 is based on an elliptical least-square fit at the middle of the femoral neck. Methods 2 and 3 defined the centre of mass of the entire femoral neck and of the most cylindrical part, respectively. Methods 4 and 5 were based on the intersection of the femoral neck with a 25% and 40% enlarged best fit sphere of the femoral head.

results3D methods resulted in higher femoral torsion measures than the 2D method; the mean torsion for method 0 was 8.12° ± 7.30°, compared to 9.93° ± 8.24° (p < 0.001), 13.21° ± 8.60° (p < 0.001), 8.21° ± 7.64° (p = 1.00), 9.53° ± 7.87° (p < 0.001) and 10.46° ± 7.83° (p < 0.001) for methods 1 to 5 respectively. In the presence of a CAM, torsion measured with method 4 is consistently smaller than measured with method 5.

conclusion2D measurement might underestimate true femoral torsion and there is a difference up to 5°. There is a tendency for a higher mean torsion in hips with a CAM deformity. Methods 4 and 5 are the most robust techniques. However, method 4 might underestimate femoral torsion if a CAM deformity is present. Since method 5 is independent of a CAM deformity, it is the preferred technique to define expected values of torsion.

Indexed as

3DCTFemoral neck axisFemoral torsionHip

Identifiers

PMID38108926
PMCPMC10728037
OpenAlexW4389900068

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.