Evidence map›Paper›PMID 38107973›Full record

ArticleACS omega2023

Development of Flexible Medical Electrodes Using Carrageenan-Based Bioplastics with the Addition of Conductive Hybrid Materials Graphite and Silver Nanoparticles.

Fathur Rahman, Damar Rastri Adhika, Akhmad Zein Eko Mustofa, Suprijanto

Open access · goldAbstract read
In one paragraph

Article in ACS omega, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Fathur RahmanMagister of Nanoscience and Nanotechnology, Graduate School, ITB, Jl. Ganesa No. 10, Bandung 40132, Indonesia.
Damar Rastri AdhikaAdvanced Functional Materials Research Group, Faculty of Industrial Technology, Institut Teknologi Bandung, Jl. Ganesa No. 10, Bandung 40132, Indonesia.ORCID https://orcid.org/0000-0003-0961-5039
Akhmad Zein Eko MustofaResearch Center for Nanoscience and Nanotechnology, ITB, Jl. Ganesa No. 10, Bandung 40132, Indonesia.
SuprijantoInstrumentation and Control Research Group, Faculty of Industrial Technology, ITB, Jl. Ganesa No. 10, Bandung 40132, Indonesia.
Bandung Institute of Technology · ID

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electrodes are crucial in medical devices, specifically health monitoring devices for biopotential measurements such as electrocardiography, electromyography (EMG), and electroencephalography. The commonly used rigid electrodes have limitations in their skin-electrode contact quality since they cannot conform to the skin's surface area and body contours. Flexible electrodes have been developed to better conform to the body's surface contours, improving ion transfer and minimizing motion artifacts, thereby enhancing the signal-to-noise ratio (SNR). Bioplastic substrates based on carrageenan have been chosen for their safety, abundance, flexibility, and ease of customization. Hybrid materials of graphite and silver nanoparticles (graphite-AgNPs) exhibit high electron capacitance, low charge transfer resistance, and superior surface catalytic activity. These make them ideal as conductive fillers for bioplastics to achieve good electrical characteristics as electrodes. The effect of the graphite-AgNP filler concentration, graphite particle size, and flexible electrode thickness was evaluated to assess their impact on the electrical and mechanical properties of the fabricated flexible electrodes. The graphite-AgNP fillers were incorporated into a bioplastic matrix, resulting in flexible electrodes with improved conductivity with increasing percentages of graphite-AgNP at the expense of flexibility. The thickness of the flexible electrode was varied to evaluate its effect on the conductivity. A graphite size reduction was performed to improve the electrical properties while maintaining the mechanical properties. The most optimal variation of flexible electrodes with desirable electrical and mechanical properties was achieved by adding 25% graphite-AgNP to the carrageenan, using graphite particles of 400-700 nm, and using the thinnest electrode. The optimized electrode also exhibited an improved SNR value in EMG signal measurements compared to conventional Ag/AgCl electrodes. This research presents a novel approach to developing environmentally friendly, customizable, and flexible electrodes for medical applications.

Identifiers

PMID38107973
PMCPMC10723651
OpenAlexW4389305462

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.