Evidence map›Paper›PMID 38107022›Full record

ArticleContinence (Amsterdam, Netherlands)2023

Development and first-in-human testing of FLUME urinary catheter with protected tip and relocated drainage holes.

Marcus J Drake, Katherine Anderson, Andrew Gammie, Nicola Morris, Tony Timlin, Nikki Cotterill, John Duff, Mandy Fader, Hazel Taylor, Roger Holmes and 1 more

Open access · goldAbstract read
In one paragraph

Article in Continence (Amsterdam, Netherlands), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.6field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 1 country.

Marcus J DrakeDepartment of Surgery and Cancer, Imperial College, London, UK.
Katherine AndersonBristol Urological Institute, North Bristol NHS trust, Bristol, UK.
Andrew GammieBristol Urological Institute, North Bristol NHS trust, Bristol, UK.
Nicola MorrisBristol Urological Institute, North Bristol NHS trust, Bristol, UK.
Tony TimlinResearch and Innovation, North Bristol NHS Trust, Bristol, UK.
Nikki CotterillSchool for Health and Social Wellbeing, University of the West of England, Bristol, UK.
John DuffPatient and Public Involvement, North Bristol NHS Trust, Bristol, UK.
Mandy FaderUniversity of Southampton, Southampton, UK.
Hazel TaylorUniversity of Bristol, Bristol, UK.
Roger HolmesThe Flume Catheter Company, UK.
John HavardThe Flume Catheter Company, UK.
North Bristol NHS Trust · GBImperial College London · GBUniversity of Bristol · GBUniversity of Southampton · GBUniversity of the West of England · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Evaluation of a catheter design which protects its tip with the retaining balloon when inflated, and has eyeholes at the base of the balloon to improve drainage. Materials and methods: Preclinical tests included assessment of retaining balloon performance, and microbiological blockage. Clinical testing evaluated short-term use and safety in hospital (stage 1) or the patient's usual residence (stage 2). Results: The retaining balloon supported static loads of 0.7kg, with reduced trauma when modelling forced evulsion. In vitro time to blockage with P. Mirabilis was significantly slower for FLUME compared with latex Foley catheters, but not the silicone Foley. Stage 1 testing (10 patients) confirmed balloon inflation, drainage, retention and removal, with no serious adverse events caused by catheterisation; one balloon failed to inflate, one patient could not be catheterised. Of five patients at stage 2, one had the catheter for 28 days without complication, one experienced spontaneous balloon deflation (14 Conclusion: FLUME catheter performed well in preclinical blockage and balloon tests. Tests in 15 patients confirmed basic function and additional training was not needed for staff familiar with Foley catheterisation. Clinical issues commonly seen with catheters included failed catheterisation, clot blockage and bypassing. In addition, an unintended balloon deflation and a failure of bag connection occurred. Plain language summary: This article describes a new catheter design which aims to improve patient comfort and safety, and maximise bladder drainage, by protecting the bladder from the exposed catheter tip and by locating the drainage holes better. Various tests were done to check the catheter retaining balloon was safe and how well the catheter did when exposed to bacteria that could block it. The catheter was also used in people for the first time, to check it could be put in safely and functioned as intended. The results showed the FLUME catheter did well in the balloon and blockage tests. Tests in 15 patients confirmed basic function and showed placement was easy for staff familiar with conventional catheters. There were some clinical issues typical of urinary catheters and some possible improvements were identified.

Indexed as

CatheterCatheter associated urinary tract infectionFirst in humanFoley catheterMicrobiology

Identifiers

PMID38107022
PMCPMC10719115
OpenAlexW4388485286

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.