Evidence map›Paper›PMID 38106450›Full record

ArticleInternational journal of nanomedicine2023

Aptamer-Based Functionalized SERS Biosensor for Rapid and Ultrasensitive Detection of Gastric Cancer-Related Biomarkers.

Ping Shao, Danyang Dong, Yong Huang, Yan Wang, Lian Pan, Qunshan Zhu, Zheng Wu, Fengjuan Jiang, Wei Wei

Abstract read
In one paragraph

Article in International journal of nanomedicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Advances in nanomedicine and delivery systems for gastric cancer research.Frontiers in bioengineering and biotechnology · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ping ShaoDepartment of Spleen and Stomach Diseases, Yixing Traditional Chinese Medicine Hospital, Wuxi, 214200, People's Republic of China.
Danyang DongDepartment of Spleen and Stomach Diseases, Yixing Traditional Chinese Medicine Hospital, Wuxi, 214200, People's Republic of China.
Yong HuangDepartment of General Surgery, Jiangdu People's Hospital Affiliated to Yangzhou University, Yangzhou, 225200, People's Republic of China.
Yan WangDepartment of Spleen and Stomach Diseases, Yixing Traditional Chinese Medicine Hospital, Wuxi, 214200, People's Republic of China.
Lian PanPathology Department, Yixing Traditional Chinese Medicine Hospital, Wuxi, 214200, People's Republic of China.
Qunshan ZhuDepartment of General Surgery, Jiangdu People's Hospital Affiliated to Yangzhou University, Yangzhou, 225200, People's Republic of China.
Zheng WuDepartment of General Surgery, Jiangdu People's Hospital Affiliated to Yangzhou University, Yangzhou, 225200, People's Republic of China.
Fengjuan JiangDepartment of Gastroenterology, Jiangdu People's Hospital Affiliated to Yangzhou University, Yangzhou, 225200, People's Republic of China.
Wei WeiDepartment of General Surgery, Jiangdu People's Hospital Affiliated to Yangzhou University, Yangzhou, 225200, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Gastric cancer (GC) as is the second deadliest malignancy still lacks rapid, simple and economical detection and early clinical screening techniques. Surface-enhanced Raman spectroscopy (SERS) is a spectroscopic technique based on the surface plasmon resonance of precious metal nanoparticles, which can effectively detect low-abundance tumor markers. Combining SERS technology with sensors has high potential in the diagnosis and screening of GC. Methods: A novel Au/Si nano-umbrella array (Au/SiNUA) was prepared as a SERS substrate and the substrate was functionalized using the corresponding tumor marker aptamers for the detection of clinical biological samples using a one-step recognition release mechanism. Optimization of aptamer and complementary chain concentrations and detection time for optimal sensor preparation. Results: Au/SiNUA were tested to have good SERS enhancement activity. The proposed aptamer biosensor has good specificity and stability, with a low detection time of 18 min and a limit of detection (LOD) at the fM level, which is superior to most of the methods reported so far; and the accuracy of the clinical assay is comparable to that of the ELISA method. The expression levels of PDGF-B and thrombin in the serum of GC patients and healthy individuals can be effectively detected and differentiated. Conclusion: The ultrasensitive and specific aptamer biosensor is highly feasible for the diagnosis and screening of GC and has good application prospects.

Indexed as

Aptamers, NucleotideBiosensing TechniquesMetal NanoparticlesStomach NeoplasmsBiomarkers, TumorGoldHumansLimit of DetectionSpectrum Analysis, RamanAptamers, NucleotideBiomarkers, TumorGoldaptamerAu/SiNUAbiosensorgastric cancersurface-enhanced Raman scattering

Identifiers

PMID38106450
PMCPMC10723598

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.