Evidence map›Paper›PMID 38106288›Full record

ArticleQuantitative imaging in medicine and surgery2023

Estimate of fetal brain temperature using proton resonance frequency thermometry during 3 Tesla fetal magnetic resonance imaging.

Jacob Ellison, Kisoo Kim, Yi Li, Xin Mu, Orit Glenn, Eugene Ozhinsky, Shabnam Peyvandi, Duan Xu

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Jacob EllisonDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
Kisoo KimDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
Yi LiDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
Xin MuDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
Orit GlennDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
Eugene OzhinskyDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
Shabnam PeyvandiDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
Duan XuDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
University of California System · USUniversity of California, San Francisco · USUniversity of California, Berkeley · US

Funding

The Risk of Acquired Neonatal Significant brain Injury during perinatal Transition in Congenital Heart Disease: TRANSIT CHD studyR01NS125404 · NINDS · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI Shabnam Peyvandi · 2022 to 2026
$2.8M
Fetal markers of neurodevelopmental outcomes in congenital heart diseaseK23NS099422 · NINDS · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI PEYVANDI, SHABNAM · 2017 to 2021
$961k
NINDS NIH HHS K23 NS099422NINDS NIH HHS R01 NS125404
6 · The paper itself

Abstract

Background: T2-weighted Single Shot Fast Spin Echo (SSFSE) scans at 3 Tesla (3T) are increasingly used to image fetal pathology due to their excellent tissue contrast resolution and signal-to-noise ratio (SNR). Temperature changes that may occur in response to radio frequency (RF) pulses used for these sequences at 3T have not been studied in human fetal brains. To evaluate the safety of T2-weighted SSFSE for fetal brains at 3T, magnetic resonance (MR) thermometry was used to measure relative temperature changes in a typical clinical fetal brain MR exam. Methods: Relative temperature was estimated using sets of gradient recalled echo (GRE) images acquired before and after T2-weighted SSFSE images which lasted 27.47±8.19 minutes. Thirty-one fetuses with cardiac abnormalities, and 20 healthy controls were included in this study. Fetal brain temperature was estimated by proton resonance frequency (PRF) thermometry and compared to the estimated temperature in the gluteal muscle of the mother. Seven scans with excessive motion were excluded. Local outlier factor (LOF) was performed to remove 12 additional scans with spurious phase measurements due to motion degradation and potential field drift. Linear regression was performed to determine if temperature changes are dependent on the rate of energy deposition during the scan. Results: For the 32 participants used in the analysis, 17 with cardiac abnormalities and 15 healthy controls, the average relative fetal temperate change was 0.19±0.73 ℃ higher than the mother, with no correlation between relative temperature change and the rate of images acquired during the scans (regression coefficient =-0.05, R-squared =0.05, P=0.22, F-statistic =1.60). The difference in the relative temperature changes between the fetal brain and mother's gluteal tissue in the healthy controls was on average 0.08 ℃ lower and found not to be statistically different (P=0.76) to the group with cardiac abnormalities. Conclusions: Our results indicate that the estimated relative temperature changes of the fetal brain compared to the mother's gluteal tissue from RF pulses during the course of the T2-weighted SSFSE fetal MR exam are minimal. The differences in acquired phase between these regions through the exam were found not to be statistically different. These findings support that fetal brain imaging at 3T is within FDA limits and safe.

Indexed as

brainfetalmagneticresonanceThermometry

Identifiers

PMID38106288
PMCPMC10722078
OpenAlexW4388986446

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.