Evidence map›Paper›PMID 38106264›Full record

ArticleQuantitative imaging in medicine and surgery2023

Whole-body magnetic resonance imaging in two minutes: cross-sectional real-time coverage of multiple volumes.

Dirk Voit, Jost M Kollmeier, Oleksandr Kalentev, Maaike van Zalk, Jens Frahm

Erratum issuedAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Dirk VoitBiomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany.
Jost M KollmeierBiomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany.
Oleksandr KalentevBiomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany.
Maaike van ZalkBiomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany.
Jens FrahmBiomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This work describes a novel technique for rapid and motion-robust whole-body magnetic resonance imaging (MRI). The method employs highly undersampled radial fast low angle shot (FLASH) sequences to cover large volumes by cross-sectional real-time MRI with automatic slice advancement after each frame. The slice shift typically amounts to a fraction of the slice thickness (e.g., 10% to 50%) in order to generate a successive series of partially overlapping sections. Joint reconstructions of these serial images and their respective coil sensitivity maps rely on nonlinear inversion (NLINV) with regularization to the image and sensitivity maps of a preceding frame. The procedure exploits the spatial similarity of neighboring sections. Whole-body scanning is accomplished by measuring multiple volumes at predefined locations, i.e., at fixed table positions, in combination with intermediate automatic movements of the patient table. Individual volumes may take advantage of different field-of-views, image orientations, spatial and temporal resolutions as well as contrasts. Preliminary proof-of-principle applications to healthy subjects at 3 T without cardiac gating and during free breathing yield high-quality anatomic images with acquisition times of less than 100 ms. Spin-density and T1 contrasts are obtained by spoiled FLASH sequences, while T2-type (i.e., T2/T1) contrast results from refocused FLASH sequences that generate a steady state free precession (SSFP) free induction decay (FID) signal. Total measuring times excluding vendor-controlled adjustment procedures are less than two minutes for a 100 cm scan that, for example, covers the body from head to thigh by three optimized volumes and more than 1,300 images. In conclusion, after demonstrating technical feasibility the proposed method awaits clinical trials.

Indexed as

rapid volume coveragereal-time magnetic resonance imaging (real-time MRI)Whole-body magnetic resonance imaging (whole-body MRI)

Identifiers

PMID38106264
PMCPMC10722042

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked