Ultrashort echo time pulse sequences for visualization of deep peripheral fasciae and epimysium in porcine models with histologic correlations.

Kun Hwang, Jang Gyu Cha, Hun Kim, Hyungseok Jang, Dae Joong Kim, Seunghun Lee, Yeo Ju Kim

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 6 institutions in 2 countries.

Kun Hwang *Department of Plastic Surgery, Armed Forces Capital Hospital, Seongnam-City, Republic of Korea.
Jang Gyu Cha *Department of Radiology, Soonchunhyang University Bucheon Hospital, Bucheon-Si, Republic of Korea.
Hun KimDivision of Trauma Surgery, Department of Surgery, Seoul National University Hospital, Seoul, Republic of Korea.
Hyungseok JangDepartment of Radiology, University of California, San Diego, San Diego, CA, USA.
Dae Joong KimDepartment of Anatomy, College of Medicine, Inha University, Incheon, Republic of Korea.
Seunghun LeeDepartment of Radiology, College of Medicine, Hanyang University, Seoul, Republic of Korea.
Yeo Ju KimDepartment of Radiology, College of Medicine, Hanyang University, Seoul, Republic of Korea.
Hanyang University · KRArmed Forces Capital Hospital · KRInha University · KRSeoul National University Hospital · KRSoonchunhyang University · KRUniversity of California San Diego · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The deep peripheral fascia and epimysium are vital for muscle and tendon support, but their tight proton composition results in hypointense signals in conventional spin echo sequences. Ultrashort echo time (UTE) magnetic resonance imaging (MRI), using microsecond TE values, may visualize these structures. The purpose of this study was to evaluate whether UTE pulse sequence with a three-dimensional cone trajectory (3D UTE), with or without fat suppression (FS), can be used to visualize the fascia and epimysium using porcine lower legs as an example. Methods: The anterior soft tissues of porcine lower legs were dissected and partially separated into distinct layers to expose the deep peripheral fascia, epimysium, and muscle. Axial 3D UTE and 3D UTE FS imaging using dual-echo acquisition and echo subtraction were performed both before and after dissection. Prior to dissection, the thickness, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) of structures believed to be deep peripheral fascia and epimysium were measured in both 3D UTE and 3D UTE FS. Post-dissection images were also analyzed to measure the SNRs and CNRs for the deep peripheral fascia and epimysium. Histological evaluations were carried out to verify the identities of the deep peripheral fascia and epimysium, as well as their thickness, and these measurements were compared to imaging findings. Results: In pre-dissection images obtained with 3D UTE and 3D UTE FS, both the deep peripheral fascia and epimysium exhibited high signal intensity. In the subtraction images, the mean thickness of the deep fascia was 0.87 mm, and that of the epimysium was 0.80 mm when imaged with 3D UTE. This is compared to measurements of 0.77 and 0.22 mm in 3D UTE FS, respectively. Histological analyses confirmed the thickness of the deep peripheral fascia and epimysium as 0.65 and 0.14 mm, respectively. In the post-dissection images, the deep fascia continued to display high signal intensity when compared with adjacent soft tissues, consistent with the histological findings. Meanwhile, the epimysium showed very low CNRs. Conclusions: 3D UTE and 3D UTE FS can be used to visualize the deep peripheral fascia with high signal intensity and contrast but are insufficient to show signal intensity in the epimysium.

Indexed as

deep peripheral fasciaepimysiumUltrashort echo time (UTE)

Identifiers

PMID38106251
PMCPMC10721985
OpenAlexW4388973717

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.