ArticleScientific reports2023
Machine learning models to predict the warfarin discharge dosage using clinical information of inpatients from South Korea.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 15 citations in OpenAlex.
- Narrow Therapeutic Index Drugs: Regulatory Frameworks, Bioequivalence, and Model-Informed Precision Dosing.Pharmaceutics · 2026Review
- Artificial intelligence and machine learning for precision warfarin dosing: a comprehensive narrative review.European journal of clinical pharmacology · 2026Review
- Review
- Artificial Intelligence (AI) in Pharmaceutical Formulation and Dosage Calculations.Pharmaceutics · 2025Review
- Machine Learning for Warfarin Therapy: A Systematic Review.Pharmaceuticals (Basel, Switzerland) · 2025Review
- Monitoring and Follow-Up of Patients on Vitamin K Antagonist Oral Anticoagulant Therapy Using Artificial Intelligence: The AIto-Control Project.Journal of clinical medicine · 2025Article
- Artificial intelligence in cardiovascular pharmacotherapy: applications and perspectives.European heart journal · 2025Review
- A Prediction Model of Stable Warfarin Doses in Patients After Mechanical Heart Valve Replacement Based on a Machine Learning Algorithm.Reviews in cardiovascular medicine · 2025Article
- Application of machine learning techniques for warfarin dosage prediction: a case study on the MIMIC-III dataset.PeerJ. Computer science · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
17 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
As warfarin has a narrow therapeutic window and obvious response variability among individuals, it is difficult to rapidly determine personalized warfarin dosage. Adverse drug events(ADE) resulting from warfarin overdose can be critical, so that typically physicians adjust the warfarin dosage through the INR monitoring twice a week when starting warfarin. Our study aimed to develop machine learning (ML) models that predicts the discharge dosage of warfarin as the initial warfarin dosage using clinical data derived from electronic medical records within 2 days of hospitalization. During this retrospective study, adult patients who were prescribed warfarin at Asan Medical Center (AMC) between January 1, 2018, and October 31, 2020, were recruited as a model development cohort (n = 3168). Additionally, we created an external validation dataset (n = 891) from a Medical Information Mart for Intensive Care III (MIMIC-III). Variables for a model prediction were selected based on the clinical rationale that turned out to be associated with warfarin dosage, such as bleeding. The discharge dosage of warfarin was used the study outcome, because we assumed that patients achieved target INR at discharge. In this study, four ML models that predicted the warfarin discharge dosage were developed. We evaluated the model performance using the mean absolute error (MAE) and prediction accuracy. Finally, we compared the accuracy of the predictions of our models and the predictions of physicians for 40 data point to verify a clinical relevance of the models. The MAEs obtained using the internal validation set were as follows: XGBoost, 0.9; artificial neural network, 0.9; random forest, 1.0; linear regression, 1.0; and physicians, 1.3. As a result, our models had better prediction accuracy than the physicians, who have difficulty determining the warfarin discharge dosage using clinical information obtained within 2 days of hospitalization. We not only conducted the internal validation but also external validation. In conclusion, our ML model could help physicians predict the warfarin discharge dosage as the initial warfarin dosage from Korean population. However, conducting a successfully external validation in a further work is required for the application of the models.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.