ArticleJournal of general internal medicine2024
Outcomes of Warfarin Home INR Monitoring vs Office-Based Monitoring: a Retrospective Claims-Based Analysis.
Article in Journal of general internal medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 9 citations in OpenAlex.
- Warfarin Patient Self-Management in the US Health Care System: A Nonrandomized Clinical Trial.JAMA network open · 2026Trial
- Trial
- Self-testing and clinical outcomes in Black and White patients on warfarin for atrial fibrillation or venous thromboembolism.Research and practice in thrombosis and haemostasis · 2026Observational
- Clinical, genetic, and nutritional determinants of INR: role of plasma warfarin and hydroxylated metabolite levels in anticoagulated Mexican patients.Journal of thrombosis and thrombolysis · 2026Article
- Unlocking the Value of Patient Self-Monitoring Technologies: A Multi-Country Framework to Calibrate Payer and HTA Coverage and Reimbursement Considerations with Innovation.Journal of health economics and outcomes research · 2026Article
- A narrative literature review on the clinical utility of activated partial thromboplastin time and anti-factor Xa activity assays in cancer patients with anticoagulant therapy.Translational cancer research · 2025Review
- Smart approach for international normalized ratio monitoring: Pakistan's perspective.Annals of medicine and surgery (2012) · 2024Article
- Comparative effectiveness of warfarin management strategies: a systematic review and network meta-analysis.EClinicalMedicine · 2024Article
- Retrospective modeling study of ChatGPT (GPT 4) warfarin dose adjustment in patients with INRs outside the therapeutic range.Digital healthArticle
- Narrative Review of Management Strategies and Risk Mitigation for Gastrointestinal Bleeding in Atrial Fibrillation Patients Receiving Warfarin.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/HemostasisReview
- Acute drug-use-related native tricuspid valve infective endocarditis: a non-surgical disease.Therapeutic advances in infectious diseaseReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundHome INR testing (patient self-testing) is feasible and effective for warfarin patients but little is known about real-world differences in outcomes for patients using PST versus laboratory-based INR monitoring.
objectiveTo compare the safety/efficacy of patient self-testing of real-world warfarin therapy versus office/lab-based monitoring of therapy. DESIGN/SETTING/PARTICIPANTS/EXPOSURE: A retrospective claims-based analysis of warfarin patients enrolled in the MarketScan® Commercial Claims and Encounters and Medicare databases between January 1, 2013, and March 30, 2020. Stratification was based on INR testing method: patient self-testing versus testing at physicians' offices/local laboratory. The probability of adverse events in each cohort was determined after adjusting for demographic and baseline clinical characteristics using a repeated measures analysis. MAIN MEASURES: Rates of all adverse events: deep venous thrombosis, pulmonary embolism, bleeding, and stroke. A secondary outcome of interest was emergency department visits. KEY
resultsA total of 37,837 patients were included in the analysis: 1592 patients in the patient self-testing group and 36,245 in the office-based therapy group. After adjusting for demographic and baseline clinical characteristics, patients in the office-based group had statistically significantly higher rates of all adverse events (incidence rate ratio [IRR]=2.07, 95% CI [1.82, 2.36]), and specific adverse events including thromboembolism (IRR=4.38, 95% CI [3.29, 5.84]), major bleed (IRR=1.45, 95% CI [1.28, 1.64]), and stroke (IRR=1.30, 95% CI [1.05, 1.61]) than patients in the patient self-testing group. Office-based patients also had a statistically significant higher rate of emergency department visits than patient self-testing patients (IRR = 1.65, 95% CI [1.47, 1.84]). CONCLUSIONS/RELEVANCE: This analysis of real-world claims data shows lower rates of stroke, thromboembolism, and major bleeding, as well as fewer emergency department visits, with patient self-testing compared to office-based/lab INR monitoring. Our finding that PST is safe and effective among current users suggests that more patients may benefit from its use.
Indexed as