ArticleThe journal of extra-corporeal technology2023
Development of new colloid osmotic pressure measurement method using ultrafiltration membrane during cardiopulmonary bypass.
Article in The journal of extra-corporeal technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundClinical practice of measuring colloid osmotic pressure (COP) was abandoned after correcting hypoosmolarity did not improve overall patient outcomes. However, the use of albumin and colloidal solutions has contributed to maintaining intraoperative and postoperative fluid balance at lower levels. Reduced perioperative fluid balance is consistently reported to have positive effects on clinical outcomes. Priming solutions for cardiopulmonary bypass typically include colloids; however, the optimal type of priming solution has not yet been determined. Stricter COP management may further improve postoperative courses. To achieve this, the widespread adoption of a measurement method suitable for COP monitoring during cardiopulmonary bypass is required.
methodsA test circuit was made which measured COP using an ultrafiltration membrane method based on the changes in hydrostatic pressure that occurs across a semipermeable membrane. We then compared the measurements obtained using this method with colloidal osmometer measurements.
resultsCOP measurements were obtained for a total of 100 tests (10 times each for 10 test solutions). The evaluation parameters included simultaneous reproducibility, correlation with the colloid osmometer, and measurement time. The results demonstrated high accuracy of the ultrafiltration membrane method, simultaneous reproducibility within 3%, a high positive correlation with the colloid osmometer (correlation coefficient: R
conclusionMeasuring COP using ultrafiltration membranes solves problems within existing measurement methods. Although further improvements in the method are necessary, it has implications for future research and clinical applications.
Indexed as