Evidence map›Paper›PMID 38098613›Full record

ArticleAustralasian journal of ultrasound in medicine2023

Hand and finger, ultrasound-guided, percutaneous core needle biopsies: A safe procedure with high diagnostic accuracy.

Stephanie Magoon, Vanessa Peters, Felipe Ferreira de Souza, David Chen, Patrick Owens, Juan Pretell-Mazzini, Natalia Fullerton, Jean Jose, Andrew Rosenberg, Ty K Subhawong

Open access · hybridAbstract read
In one paragraph

Article in Australasian journal of ultrasound in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Multifaceted uses for musculoskeletal ultrasound.Australasian journal of ultrasound in medicine · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Stephanie MagoonLeonard M. Miller School of Medicine, University of Miami Miami Florida USA.ORCID https://orcid.org/0000-0003-0928-7207
Vanessa PetersLeonard M. Miller School of Medicine, University of Miami Miami Florida USA.
Felipe Ferreira de SouzaDepartment of Radiology University of Miami Miller School of Medicine and the Sylvester Comprehensive Care Center Miami Florida USA.
David ChenDepartment of Orthopedic Surgery University of Miami Miller School of Medicine and the Sylvester Comprehensive Care Center Miami Florida USA.
Patrick OwensDepartment of Orthopedic Surgery University of Miami Miller School of Medicine and the Sylvester Comprehensive Care Center Miami Florida USA.
Juan Pretell-MazziniDepartment of Orthopedics Herbert Wertheim College of Medicine, Florida International University Miami Florida USA.
Natalia FullertonDepartment of Plastic Surgery University of Miami Miller School of Medicine and the Sylvester Comprehensive Care Center Miami Florida USA.
Jean JoseDepartment of Radiology University of Miami Miller School of Medicine and the Sylvester Comprehensive Care Center Miami Florida USA.
Andrew RosenbergDepartment of Pathology University of Miami Miller School of Medicine and the Sylvester Comprehensive Care Center Miami Florida USA.
Ty K SubhawongDepartment of Radiology University of Miami Miller School of Medicine and the Sylvester Comprehensive Care Center Miami Florida USA.
University of Miami · USFlorida International University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction/Purpose: To determine the diagnostic accuracy and complication rates of ultrasound-guided, percutaneous core needle biopsies of soft tissue masses in the hand and fingers. Methods: Reports from all ultrasound-guided procedures between 21 May 2014 and 17 March 2022 were queried for keywords including "hand", OR "finger", AND "biopsy". Patient demographics, lesion size and location, biopsy needle gauge and the number of cores obtained were recorded. The final pathology of the mass excision was then compared with the core needle biopsy (CNB) for each patient. Results: Sixty-six records were reviewed, and 37 patients met inclusion criteria. Maximum lesion diameter averaged 1.45 cm with a range between 0.4 and 4.3 cm. The frequency of needle gauges used was 14G (14%), 16G (24%), 18G (38%), 20G (11%) and 'not reported' (14%). The mean number of tissue cores obtained was 2.9 (SD 1.2; range 1 to 6), excluding nine cases that reported 'multiple'. The frequency of CNB diagnoses included tenosynovial giant cell tumour (TGCT) at 30%, ganglion cyst at 11% and epidermal inclusion cyst at 5%. CNB was 100% sensitive in detecting the three (8%) malignancies. Of the 37 tumours biopsied, 16 were surgically excised. One angiomyoma was originally diagnosed as a haemangioma on CNB, but all other histologic results were concordant for a diagnostic accuracy of 97%. Discussion: Small soft tissue masses in the hands and fingers, even those less than 1 cm, are often amenable to ultrasound-guided CNB. Performance under image guidance facilitates retrieval of core specimens adquate for histologic diagnosis with relatively few passes using higher gauge needles. Conclusion: Overall, ultrasound-guided CNB of the hand and fingers is safe and highly accurate in diagnosing soft tissue tumours. The accuracy is unrelated to the needle's gauge, the number of passes and the size of the lesions.

Identifiers

PMID38098613
PMCPMC10716568
OpenAlexW4387900988

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.