ReviewBMC cardiovascular disorders2023
Left atrial Thrombus formation after discontinuation of anticoagulation in patient with severe bioprosthetic mitral stenosis.
Review in BMC cardiovascular disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMitral valve stenosis can be a highly symptomatic condition with significant complications if left untreated. In such cases, mitral valve replacement with a bioprosthetic or mechanical valve may be a viable solution to prevent progressive disease. Current guidelines do not recommend continued anticoagulation beyond 6 months for patients who have undergone bioprosthetic valve replacement without a separate indication for anticoagulation. With this case discussion we aim to 1) Review the current indications for anticoagulation for bioprosthetic mitral valves in patients without atrial fibrillation and 2) Discuss the constellation of comorbidities that may affect the decision to begin anticoagulation therapy. CASE PRESENTATION: We present a case describing a 55-year-old male with end-stage renal disease, coronary artery disease with coronary artery bypass graft surgery, and bioprosthetic mitral valve replacement 2 years prior with rapid degeneration of the replaced valve and on warfarin without a clear indication for anticoagulation. The patient was admitted for symptomatic, severe mitral stenosis and consideration of transcatheter mitral valve-in-valve replacement. During hospital admission, warfarin was discontinued and replaced with prophylactic anticoagulation. However, 8 days after warfarin cessation an intraoperative transesophageal echocardiography revealed a newly developed large left atrial thrombus leading to cancellation of the planned operation.
conclusionsThis patient developed a left atrial thrombus after discontinuing warfarin in the setting of rapidly deteriorating bioprosthetic valve stenosis and vascular comorbidities. The decision to discontinue warfarin was made in concordance with current guidelines, which do not indicate systemic anticoagulation post 3-6 months after bioprosthetic valve replacement without separate indication for anticoagulation. This case identifies the need to investigate rebound hypercoagulability and further risk stratify comorbidities which may independently increase the risk of clot formation in the setting of severe mitral valve stenosis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.