Evidence map›Paper›PMID 38096037›Full record

ArticleIUCrJ2024

Dynamic X-ray speckle-tracking imaging with high-accuracy phase retrieval based on deep learning.

Fucheng Yu, Kang Du, Xiaolu Ju, Feixiang Wang, Ke Li, Can Chen, Guohao Du, Biao Deng, Honglan Xie, Tiqiao Xiao

Abstract read
In one paragraph

Article in IUCrJ, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Fucheng YuShanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People's Republic of China.
Kang DuShanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, People's Republic of China.
Xiaolu JuShanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, People's Republic of China.
Feixiang WangShanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People's Republic of China.
Ke LiShanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People's Republic of China.
Can ChenZhejiang Institute of Metrology, Hangzhou 310063, People's Republic of China.
Guohao DuShanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People's Republic of China.
Biao DengShanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People's Republic of China.
Honglan XieShanghai Synchrotron Radiation Facility/Zhang Jiang Lab, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201800, People's Republic of China.ORCID 0000-0003-0448-042X
Tiqiao XiaoShanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, People's Republic of China.

Funding

National Key Research and Development Program of China 2017YFA0206004National Key Research and Development Program of China 2021YFA1600703National Key Research and Development Program of China 2021YFF0601203National Key Research and Development Program of China 2022YFA1603601National Natural Science Foundation of China 81430087
6 · The paper itself

Abstract

Speckle-tracking X-ray imaging is an attractive candidate for dynamic X-ray imaging owing to its flexible setup and simultaneous yields of phase, transmission and scattering images. However, traditional speckle-tracking imaging methods suffer from phase distortion at locations with abrupt changes in density, which is always the case for real samples, limiting the applications of the speckle-tracking X-ray imaging method. In this paper, we report a deep-learning based method which can achieve dynamic X-ray speckle-tracking imaging with high-accuracy phase retrieval. The calibration results of a phantom show that the profile of the retrieved phase is highly consistent with the theoretical one. Experiments of polyurethane foaming demonstrated that the proposed method revealed the evolution of the complicated microstructure of the bubbles accurately. The proposed method is a promising solution for dynamic X-ray imaging with high-accuracy phase retrieval, and has extensive applications in metrology and quantitative analysis of dynamics in material science, physics, chemistry and biomedicine.

Indexed as

computed tomographydeep learningdynamic X-ray imagingphase contrast X-ray imagingphase retrievalspeckle trackingX-ray microscopy

Identifiers

PMID38096037
PMCPMC10833393

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.