ArticleJMIR formative research2023
Assessment of Heart Rate Monitoring During Exercise With Smart Wristbands and a Heart Rhythm Patch: Validation and Comparison Study.
Article in JMIR formative research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06410755 (Research on Evaluation of Home-based Rehabilitation Monitoring System With Wearable Devices and Self-Report Application), which is not on this map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Research on Evaluation of Home-based Rehabilitation Monitoring System With Wearable Devices and Self-Report Application
Who cites it
1 citing paper in PubMed.
- Innovation and challenges of artificial intelligence technology in personalized healthcare.Scientific reports · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe integration of wearable devices into fitness routines, particularly in military settings, necessitates a rigorous assessment of their accuracy. This study evaluates the precision of heart rate measurements by locally manufactured wristbands, increasingly used in military academies, to inform future device selection for military training activities.
objectiveThis research aims to assess the reliability of heart rate monitoring in chest straps versus wearable wristbands.
methodsData on heart rate and acceleration were collected using the Q-Band Q-69 smart wristband (Mobile Action Technology Inc) and compared against the Zephyr Bioharness standard measuring device. The Lin concordance correlation coefficient, Pearson product moment correlation coefficient, and intraclass correlation coefficient were used for reliability analysis.
resultsParticipants from a Northern Taiwanese medical school were enrolled (January 1-June 31, 2021). The Q-Band Q-69 demonstrated that the mean absolute percentage error (MAPE) of women was observed to be 13.35 (SD 13.47). Comparatively, men exhibited a lower MAPE of 8.54 (SD 10.49). The walking state MAPE was 7.79 for women and 10.65 for men. The wristband's accuracy generally remained below 10% MAPE in other activities. Pearson product moment correlation coefficient analysis indicated gender-based performance differences, with overall coefficients of 0.625 for women and 0.808 for men, varying across walking, running, and cooldown phases.
conclusionsThis study highlights significant gender and activity-dependent variations in the accuracy of the MobileAction Q-Band Q-69 smart wristband. Reduced accuracy was notably observed during running. Occasional extreme errors point to the necessity of caution in relying on such devices for exercise monitoring. The findings emphasize the limitations and potential inaccuracies of wearable technology, especially in high-intensity physical activities.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.