Evidence map›Paper›PMID 38095628›Full record

ArticleAnalytical chemistry2023

Print-Pause-Print Fabrication of Tailored Electrochemical Microfluidic Devices.

Juan F Hernández-Rodríguez, Daniel Rojas, Alberto Escarpa

Open access · hybridAbstract read
In one paragraph

Article in Analytical chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.3field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Juan F Hernández-RodríguezDepartment of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, 28805 Madrid, Spain.
Daniel RojasDepartment of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, 28805 Madrid, Spain.ORCID 0000-0002-4404-4668
Alberto EscarpaDepartment of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, 28805 Madrid, Spain.ORCID 0000-0002-7302-0948
Universidad de Alcalá · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Three-dimensional (3D) printing technology has emerged as a powerful technology for the fabrication of low-cost microfluidics. Nevertheless, the fabrication of microfluidic devices integrating high-performance electrochemical sensors in practical applications is still an open challenge. Although automatic fabrication of the microfluidic device and the electrodes can be successfully carried out using a one-step multimaterial fused filament fabrication (FFF) approach, the as-printed electrochemical performance of these electrodes is not good enough for chemical (bio)sensing and their surface modification is challenging because after closing the channel there is no physical access to the electrode. Thus, here a pause-print-pause (PPP) microfabrication approach was implemented. The fabrication was paused before printing the microfluidics, and the filament-based electrodes were directly modified on the printing bed via stencil printing, drop casting, and electrodeposition. To exemplify this versatile workflow, the design of a microfluidic glucose sensor was proposed. To this end, first, the working and counter electrodes were stencil printed with graphite ink while the reference electrode was stencil printed with Ag|AgCl ink. Then, Prussian blue was formed on the working electrode either by drop casting or by electrodeposition, and glucose oxidase was drop cast on top. At this point, the microfabrication process was resumed, and the microfluidics were printed on top of the modified electrodes to complete the construction of hybrid electrochemical fluidic fused filament fabricated devices (h-eF

Identifiers

PMID38095628
PMCPMC10753525
OpenAlexW4389729460

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.