Evidence map›Paper›PMID 38095515›Full record

ArticlePolish journal of microbiology2023

Diagnostic Efficacy of Photostimulated Chemiluminescence Assay for Detecting Anti-HIV Antibodies: A Retrospective Study.

Jianxiang Han, Yong Wang, Bei Wang, Huacheng Tong

Open access · goldAbstract read
In one paragraph

Article in Polish journal of microbiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Jianxiang HanDepartment of Clinical Laboratory, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, China.
Yong WangDepartment of Clinical Laboratory, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, China.
Bei WangDepartment of Clinical Laboratory, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, China.
Huacheng TongDepartment of Clinical Laboratory, Nanjing Tongren Hospital, School of Medicine, Southeast University, Nanjing, China.
Southeast University · CNTongren Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The transmission of human immunodeficiency virus (HIV) through blood poses a slightly increased risk. As a result, patients requiring blood transfusions should be screened for HIV antibodies. This study examined the diagnostic effectiveness of the photostimulated chemiluminescence assay in detecting anti-HIV antibodies and determined the cut-off value for this method. The performance of the fully automated photostimulated chemiluminescence assay system was validated according to CNAS-GL038:2019 (2020) and CNAS-GL037:2019 (2019) guidelines. A retrospective study was conducted at the Department of Medical Laboratory, Nanjing Tongren Hospital, affiliated with Southeast University, from January 2020 to December 2022. A total of 77,386 cases were tested for anti-HIV antibodies using the photostimulated chemiluminescence assay, with 79 cases initially testing positive. The method's performance in detecting anti-HIV antibodies was evaluated using the Receiver Operating Characteristic (ROC) curve and the average Coefficient of Variation (CV) value of 3-year in-house quality control. The precision, detection limit, coincidence rate, and critical value of the performance verification results met the requirements. Using Western blotting (WB) as the reference method, positive cases were initially screened using the light-induced chemiluminescence method to determine the cut-off index (COI) value and draw the ROC curve. The maximum area under the ROC curve using the chemiluminescence method was 0.997, with a cutoff value of < 28.56, sensitivity of 98%, specificity of 100%, Jordan index of 0.98, and an average CV value of 3.55%. In conclusion, the photostimulated chemiluminescence assay has good diagnostic efficacy in detecting anti-HIV antibodies and is suitable for rapid screening before blood transfusion and surgery.

Indexed as

HIV-1HIV AntibodiesHumansLuminescenceRetrospective StudiesROC CurveSensitivity and SpecificityHIV Antibodiesanti-HIVblood transfusiondiagnostic efficiencyphotostimulated chemiluminescence assay

Identifiers

PMID38095515
PMCPMC10725179
OpenAlexW4389685283

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.