Evidence map›Paper›PMID 38094902›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2023

Image denoising in fluorescence microscopy using feature based gradient reconstruction.

Suman Kumar Maji, Hussein Yahia

Open access · greenAbstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 55% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 2 countries.

Suman Kumar MajiIndian Institute of Technology Patna, Department of Computer Science and Engineering, Patna, Bihar, India.ORCID https://orcid.org/0000-0003-4019-0980
Hussein YahiaTeam Geostat, INRIA Bordeaux Sud-Ouest, Talence Cedex, France.
Centre de Recherche Inria Bordeaux - Sud-Ouest · FRIndian Institute of Technology Patna · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The utility of fluorescence microscopy imaging comes with the challenge of low resolution acquisitions, which severely limits information extraction and quantitative analysis. Image denoising is a technique that aims to remove noise from microscopy acquisitions by taking into account prior statistics of the corrupting noise. In this work, we propose an image denoising technique for fluorescence microscopy imaging. Approach: The proposed technique is based on the principle of multifractal feature extraction from a noisy sample followed by a reconstruction technique from these features. It is observed that by following a proper hierarchical classification procedure, meaningful features can be extracted from a noisy image. A denoised image is then estimated from this sparse feature set through proper formulation of an optimization problem. Results: Experiments are performed on both synthetic image databases as well as on real fluorescence microscopy data. Superior denoising results, in comparison to multiple comparing techniques, validate the potential of the proposed approach. Conclusion: The proposed method gives superior denoising results for low resolution fluorescence microscopy image acquisitions and can be used for post processing of data by biologists.

Indexed as

fluorescence microscopyimage denoisingPoisson–Gaussian noisesingularity exponents

Identifiers

PMID38094902
PMCPMC10715713
OpenAlexW4389611382

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.