ArticleCureus2023
Characterization of an Onboard Transmission Detector for Efficient Linear Accelerator Output Quality Assurance.
Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose To investigate the potential to perform linear accelerator output quality assurance (QA) with the ScandiDos Delta4 Discover (Discover) onboard transmission detector. Materials and methods Using the ScandiDos Delta4 software (version 8), a conversion factor from raw signal to output was obtained via cross-calibration with an accredited dosimetry calibration laboratory (ADCL) calibrated ionization chamber for each photon energy, including flattening-filter-free (FFF) energies. With the calibration factor for 6 MV (6x) photon energy, output measurements were taken with both the Delta4 Discover and ion chamber and compared for output as a function of gantry angle and dose-rate dependence. Monitor unit (MU) linearity for 6x was measured and compared with ion chamber measurements. Additionally, the Discover was used to take output measurements, for 6x, approximately every hour throughout the course of a treatment day, and compared with ion chamber output measurements at the beginning and end of the treatment day. Results Output measurements for each photon energy were comparable with a maximum difference of -0.57% for flattened beams (6x) and 0.21% for FFF beams (10FFF). Output measurements using the Discover matched ion chamber output measurements at every dose rate within 2%, and within 1% for output as a function of gantry angle. MU linearity test agreed with ion chamber measurements with a maximum difference of 0.41%. Output measurements using the Discover showed a daily drift in output throughout the course of a treatment day of around 2% and correlated very well with ion chamber outputs measured at the beginning and end of the treatment day (within 0.2%). Conclusions The ScandiDos Delta4 Discover onboard transmission detector is able to accurately measure linear accelerator output comparable to ion chamber measurements.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.