Evidence map›Paper›PMID 38093536›Full record

ArticleSe pu = Chinese journal of chromatography2023

[Application progress of on-line sample preparation techniques coupled with liquid chromatography-mass spectrometry system in the detection of food hazards].

Hongwen Zhai, Hongyu Ma, Meirong Cao, Mingxing Zhang, Junmei Ma, Yan Zhang, Qiang Li

Open access · bronzeAbstract readEnglish Abstract
In one paragraph

Article in Se pu = Chinese journal of chromatography, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 56% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Hongwen ZhaiHebei Food Safety Key Laboratory, Key Laboratory of Special Food Supervision Technology for State Market Regulation, Hebei Engineering Research Center for Special Food Safety and Health, Hebei Food Inspection and Research Institute, Shijiazhuang 050227, China.
Hongyu MaHebei Food Safety Key Laboratory, Key Laboratory of Special Food Supervision Technology for State Market Regulation, Hebei Engineering Research Center for Special Food Safety and Health, Hebei Food Inspection and Research Institute, Shijiazhuang 050227, China.
Meirong CaoHebei Food Safety Key Laboratory, Key Laboratory of Special Food Supervision Technology for State Market Regulation, Hebei Engineering Research Center for Special Food Safety and Health, Hebei Food Inspection and Research Institute, Shijiazhuang 050227, China.
Mingxing ZhangHebei Food Safety Key Laboratory, Key Laboratory of Special Food Supervision Technology for State Market Regulation, Hebei Engineering Research Center for Special Food Safety and Health, Hebei Food Inspection and Research Institute, Shijiazhuang 050227, China.
Junmei MaHebei Food Safety Key Laboratory, Key Laboratory of Special Food Supervision Technology for State Market Regulation, Hebei Engineering Research Center for Special Food Safety and Health, Hebei Food Inspection and Research Institute, Shijiazhuang 050227, China.
Yan ZhangHebei Food Safety Key Laboratory, Key Laboratory of Special Food Supervision Technology for State Market Regulation, Hebei Engineering Research Center for Special Food Safety and Health, Hebei Food Inspection and Research Institute, Shijiazhuang 050227, China.
Qiang LiHebei Food Safety Key Laboratory, Key Laboratory of Special Food Supervision Technology for State Market Regulation, Hebei Engineering Research Center for Special Food Safety and Health, Hebei Food Inspection and Research Institute, Shijiazhuang 050227, China.
Hebei Food Inspection and Research Institute · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Food safety has received increased attention, and food detection is of great significance. The food matrix is complex, and diverse food hazards have been identified. Thus, the detection methods and sample preparation techniques for food matrices must be continuously optimized and updated. Several steps are usually required when a chromatographic system is used to determine food hazards: sample preparation, that is, the separation of targets from different substrates using a suitable preprocessing method and target-substance separation and purification, which is usually achieved using chromatographic separation. The selection of an appropriate detector for qualitative and quantitative analyses is usually based on the properties of the target compound. The sample preparation procedure is considered the most time-consuming aspect of the entire food-analysis process. It is also prone to analytical errors. Therefore, optimization of the sample preparation process is a key issue in the field of chemical analysis. Researchers have developed a series of new, efficient, and accurate sample preprocessing methods, and an on-line sample-preparation system has been found to be a feasible approach. On-line sample preparation coupled with liquid chromatography-mass spectrometry (LC-MS) presents many advantages. First, manual operation could reduce analytical errors to ensure good accuracy and repeatability. It could also reduce the consumption of chemical reagents and avoid cross-contamination between samples. Furthermore, an on-line sample-preparation system could shorten the sample-preparation time and improve the detection efficiency. On-line sample preparation coupled with LC-MS has been widely applied in the fields of environment, biology, and food. On-line sample preparation systems coupled with LC-MS are divided into two modules: the first modules involves sample preparation and the second module involves the LC system. The first module remove impurities and isolates the target compounds in preparation for their qualitative and quantitative detection. The coupling of these two modules depends mainly on valve switching. In this paper, we introduce the most frequently used on-line sample-preparation techniques, including on-line solid phase extraction (on-line SPE), in-tube solid phase microextraction (in-tube SPME), and turbulent chromatography (TFC). We then describe the basic principles and coupling equipment of these three on-line analytical technologies in detail. The coupling equipment establishes a physical connection between the two modules. Next, we discuss the properties of different purification fillers in an on-line sample-preparation column. The applications and research progress of on-line systems for pesticide residues, veterinary drug residues, and biotoxins are also discussed. Compared with offline sample preparation, on-line analytical systems present several advantages. On-line analytical systems can not only greatly reduce the analysis time and solvent consumption but also improve the detection sensitivity and accuracy. Such systems can be used to determine food hazards to ensure food safety. Finally, the existing problems and development trends of on-line analytical systems are discussed and prospected. To promote the applications of on-line analytical technology in food-safety detection, we suggest that the following three aspects be considered. First, more on-line purification columns with novel fillers, in addition to C18 or polymer fillers, should be developed. Second, compared with ordinary detectors, high-resolution MS detectors have better precision and accuracy. Coupling on-line analytical technologies with a high-resolution mass spectrometer may be beneficial for the further development of on-line analyses. Third, different food matrices should be compared and evaluated to continuously optimize the detection process and improve the efficiency of on-line analytical systems. As concerns regarding food safety issues have increased, the applications of on-line analytical technologies for food detection can be expected to become increasingly important.

Indexed as

Solid Phase MicroextractionChromatography, High Pressure LiquidGas Chromatography-Mass SpectrometryMass SpectrometrySolid Phase Extractionfood hazardsin-tube solid phase microextraction (in-tube SPME)on-line sample preparation techniqueson-line solid phase extraction (on-line SPE)reviewturbulent flow chromatography (TFC)

Identifiers

PMID38093536
PMCPMC10719810
OpenAlexW4389801313

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.