ArticleSystematic reviews2023
Attributes of errors, facilitators, and barriers related to rate control of IV medications: a scoping review.
Article in Systematic reviews, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Nursing Perceptions of the Intended Use of Artificial Intelligence to Prevent Medication Errors: A Qualitative Descriptive Study.Journal of clinical nursing · 2026Article
- Evaluation of Interruptions During IV Smart Pump Medication Administration in Intensive Care Units.Journal of patient safety · 2026Observational
- Enhancing Patient Safety and Charge Capture Through Smart Infusion Pump Interoperability: A Health Economic Analysis for US Health Systems.ClinicoEconomics and outcomes research : CEOR · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
backgroundIntravenous (IV) medication is commonly administered and closely associated with patient safety. Although nurses dedicate considerable time and effort to rate the control of IV medications, many medication errors have been linked to the wrong rate of IV medication. Further, there is a lack of comprehensive studies examining the literature on rate control of IV medications. This study aimed to identify the attributes of errors, facilitators, and barriers related to rate control of IV medications by summarizing and synthesizing the existing literature.
methodsThis scoping review was conducted using the framework proposed by Arksey and O'Malley and PRISMA-ScR. Overall, four databases-PubMed, Web of Science, EMBASE, and CINAHL-were employed to search for studies published in English before January 2023. We also manually searched reference lists, related journals, and Google Scholar.
resultsA total of 1211 studies were retrieved from the database searches and 23 studies were identified from manual searches, after which 22 studies were selected for the analysis. Among the nine project or experiment studies, two interventions were effective in decreasing errors related to rate control of IV medications. One of them was prospective, continuous incident reporting followed by prevention strategies, and the other encompassed six interventions to mitigate interruptions in medication verification and administration. Facilitators and barriers related to rate control of IV medications were classified as human, design, and system-related contributing factors. The sub-categories of human factors were classified as knowledge deficit, performance deficit, and incorrect dosage or infusion rate. The sub-category of design factor was device. The system-related contributing factors were classified as frequent interruptions and distractions, training, assignment or placement of healthcare providers (HCPs) or inexperienced personnel, policies and procedures, and communication systems between HCPs.
conclusionsFurther research is needed to develop effective interventions to improve IV rate control. Considering the rapid growth of technology in medical settings, interventions and policy changes regarding education and the work environment are necessary. Additionally, each key group such as HCPs, healthcare administrators, and engineers specializing in IV medication infusion devices should perform its role and cooperate for appropriate IV rate control within a structured system.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.