ArticleSurgical endoscopy2024
Effects of a force feedback function in a surgical robot on the suturing procedure.
Article in Surgical endoscopy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Impact of the force feedback feature on transoral robotic surgery.Journal of robotic surgery · 2026Article
- Objective characterization of object-specific grasping behavior during robot-assisted pulmonary resection using intraoperative force data.General thoracic and cardiovascular surgery · 2026Article
- Initial experience with the Saroa surgical system for early-stage lung cancer: a comparative study with the da Vinci surgical system.Surgery today · 2026Article
- Enhanced surgical efficiency with the next-generation da Vinci 5 system compared with da Vinci Xi: a retrospective cohort study in total laparoscopic hysterectomy.Journal of robotic surgery · 2026Article
- Usefulness of the BirdView™ in preventing devices from being lost visual field during robotic surgery using the Hugo™ RAS system: a prospective study.Surgical endoscopy · 2025Article
- Effectiveness of haptic feedback during local and remote robotic surgery: single-blind cadaveric study.Journal of robotic surgery · 2025Article
- Initial Experience with the Saroa Surgical System in Robot-Assisted Hysterectomy: First Clinical Case Series and Haptic Feedback Assessment.Medicina (Kaunas, Lithuania) · 2025Article
- Novel force feedback technology improves suturing in robotic-assisted surgery: a pre-clinical study.Surgical endoscopy · 2025Article
- Evaluation of forces applied to tissues during robotic-assisted surgical tasks using a novel force feedback technology.Surgical endoscopy · 2024Article
- Revolutionary Advances of Robotic Surgery in Urology Field.Juntendo Iji zasshi = Juntendo medical journal · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
backgroundCurrently, widely used robotic surgical systems do not provide force feedback. This study aimed to evaluate the impact and benefits of a force feedback function on the suturing procedure.
methodsTwenty surgeons were recruited and divided into young (Y-group, n = 11) and senior (S-group, n = 9) groups, based on their years of surgical experience. The effect of the force feedback function on suturing quality was evaluated using an objective assessment system (A-LAP mini, Kyoto Kagaku Co., Ltd., Kyoto, Japan). Each participant completed the suturing task on intestinal model sheets with the robotic contact force feedback on and off. The task accomplishment time (s), maximal force (Newton, N) applied to the robotic forceps, and quality of suturing (assessed by A-LAP mini) were recorded as performance parameters.
resultsIn total, the maximal force applied to the robotic forceps was significantly decreased with the robotic force feedback switched on (median [interquartile range]: 2.8 N (2.3-3.2)) as compared with when the feedback was switched off (3.4 N (2.7-4.0), P < 0.001). The contact force feedback function did not affect the objectively assessed suturing score (18 points (17.7-19.0) versus 18 points (17.0-19.0), P = 0.421). The contact force feedback function slightly shortened the task accomplishment time in the Y-group (552.5 s (466.5-832) versus 605.5 s (476.2-689.7), P = 0.851) but not in the S-group (566 s (440.2-703.5) versus 470.5 s (419.7-560.2), P = 0.164).
conclusionsWith the contact force feedback function, the suturing task was completed with a smaller maximal force, while maintaining the quality of suturing. Because the benefits are more apparent in young surgeons, robots with the contact force feedback function will facilitate the educational process in novice surgeons.
Indexed as
Identifiers
38092971What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.