Evidence map›Paper›PMID 38092083›Full record

ArticleMagnetic resonance imaging2024

Correction of phase offset errors and quantification of background noise, signal-to-noise ratio, and encoded-displacement uncertainty on DENSE MRI for kinematics of the descending thoracic and abdominal aorta.

Johane Bracamonte, Uyen Truong, John Wilson, Joao Soares

Open access · greenAbstract read
In one paragraph

Article in Magnetic resonance imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 63% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Johane BracamonteDepartment of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA.
Uyen TruongDepartment of Pediatrics, Division of Cardiology, Virginia Commonwealth University School of Medicine, Richmond, VA, USA.
John WilsonDepartment of Biomedical Engineering and Pauley Heart Center, Virginia Commonwealth University, VA, USA.
Joao SoaresDepartment of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA, USA. Electronic address: jsoares@vcu.edu.
Virginia Commonwealth University · US

Funding

Research Supplement to Promote Diversity in Health Related ResearchUL1TR002649 · NCATS · VIRGINIA COMMONWEALTH UNIVERSITY · PI MOELLER, FREDERICK GERARD · 2018 to 2022
$19.1M
Non-invasive Assessment of Pulmonary Vascular Structure/Function by MRI in Children with Pulmonary Arterial HypertensionK23HL135352 · NHLBI · VIRGINIA COMMONWEALTH UNIVERSITY · PI TRUONG, UYEN T · 2017 to 2021
$849k
NCATS NIH HHS UL1 TR002649NHLBI NIH HHS K23 HL135352
6 · The paper itself

Abstract

Displacement encoding with stimulated echoes (DENSE) MRI is a phase contrast technique that allows the encoding of tissue displacement into the phase of the magnetic resonance signal. Recent developments in this technique allow the imaging of relatively thin structures such as the aortic wall. Quantifying background noise associated to DENSE MRI is required to assess the uncertainty of derived displacement measurements and for the design and implementation of adequate noise-reduction techniques. Although noise and error management of cardiac DENSE MRI has been previously studied, developments for aortic applications are scarce. Herein, we evaluate the noise and uncertainty of DENSE MRI scans at three different locations along the descending aorta: the distal aortic arch (DAA), the descending thoracic aorta (DTA), and infrarenal abdominal aorta (IAA). Additionally, we analyze three datasets from in vitro validation experiments with polyvinyl alcohol phantoms. We implement and evaluate the effectiveness of an offset-error correction algorithm and noise filtering techniques on DENSE MRI for aortic motion applications. Our results show that the phase signal of pixels composing the static background was normally distributed, centered on average at 0.003 ± 0.02 rad and - 0.02 ± 0.024 rad for each phase directions, suggesting that background noise is random, isotropic, and DENSE MRI has little offset errors. However, background signal noise significantly increased with elapsed time of the cardiac cycle; and was spatially heterogeneous consistently increased towards the anterior space. Background noise showed no significant differences between the 3 aortic locations and the in vitro experiments. However, SNR depended on the displacement of the region of interest, in consequence it was found significantly larger at DAA (16.7 ± 8.5, p = 0.003) and DTA (15.4 ± 7.6, p = 0.008) than at the IAA (8.0 ± 4.1), but not significantly different than the SNR of in vitro experiments (8.0 ± 3.7), and had an overall average of 13 ± 7. The applied methods significantly reduced the offset error and effect of noise on the estimation of encoded displacements. Finally, this analysis suggests that the implemented DENSE MRI protocol is adequate to assess the motion of healthy human aortas. However, the relative effect of noise increased considerably on the analysis of an ageing or diseased aortas with impaired mobility, calling for further analyses on pathologically stiffened aortas.

Indexed as

Abdominal aortaDENSE MRIDescending aortaDisplacement encodingDisplacement uncertaintySignal-to-noise ratioSNRThoracic aorta

Identifiers

PMID38092083
PMCPMC10842810
OpenAlexW4389580693

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.