ArticleClinics (Sao Paulo, Brazil)2024
The intra- and inter-rater reproducibility of bone level measurements at strategic mini-implants using dental panoramic radiography.
Article in Clinics (Sao Paulo, Brazil), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- Article
- Accuracy of implant height and width measurement with triaxial rotation method based on cone-beam CT.Heliyon · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThis experimental study focused on the intra- and inter-rater reproducibility of vertical bone level (VBL) measurements at strategic mini-implants (MI) using digital panoramic radiographs (PR). STUDY
designVBLs of 152 MIs for removable partial denture stabilization at 50 randomly chosen PRs from a clinical trial were digitally evaluated by three ratters. Rater deviations exceeding 0.5 mm were re-examined. The intra-class correlation coefficient (ICC) was applied to estimate reliability. The smallest detectable change (SDC) was interrelated to the minimal clinically important change of 0.2 mm.
resultsThe first measurement round revealed intra- and inter-rater ICCs of > 0.8. However, 28 sites (9 %) were unreadable, and 97 sites (32 %) revealed differences between observers of ≥ 0.5 mm. Following a consensus session and re-training, an additional 8 sites were excluded and all remaining VBL differences were ≤ 0.5 mm. Thus, the SDCs with 95 % credibility were improved from 0.73 to 0.31 mm in the intra-rater and from 1.52 to 0.34 mm in the inter-rater statistics. Given a 50 % credibility for this special setting, both the intra- and inter-rater SDCs were 0.11 mm.
conclusionsDigital PR can be reliably utilized to determine VBLs around MIs under conditions of at least two trained observers, mutual calibration sessions, and exclusion of unquantifiable radiographs. GERMAN CLINICAL TRIALS REGISTER ID: DRKS00007589, www.germanctr.de.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.