Evidence map›Paper›PMID 38091124›Full record

ArticleMikrochimica acta2023

An electrochemical sensor based on carbon composites derived from bisbenzimidazole biphenyl coordination polymers for dihydroxybenzene isomers detection.

Yan Zhang, Wei Liu, Wei Yao, Le Kang, Enjun Gao, Vladimir P Fedin

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. A 1D [Ni(L)(HMolecules (Basel, Switzerland) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yan ZhangChina-Russian Institute of Engineering Materials Chemistry, School of Chemical Engineering, University of Science and Technology Liaoning, Anshan, Liaoning, 114051, People's Republic of China.
Wei LiuChina-Russian Institute of Engineering Materials Chemistry, School of Chemical Engineering, University of Science and Technology Liaoning, Anshan, Liaoning, 114051, People's Republic of China.
Wei YaoChina-Russian Institute of Engineering Materials Chemistry, School of Chemical Engineering, University of Science and Technology Liaoning, Anshan, Liaoning, 114051, People's Republic of China. yaowei@ustl.edu.cn.ORCID http://orcid.org/0000-0002-6750-7565
Le KangChina-Russian Institute of Engineering Materials Chemistry, School of Chemical Engineering, University of Science and Technology Liaoning, Anshan, Liaoning, 114051, People's Republic of China.
Enjun GaoChina-Russian Institute of Engineering Materials Chemistry, School of Chemical Engineering, University of Science and Technology Liaoning, Anshan, Liaoning, 114051, People's Republic of China. enjungao@163.com.
Vladimir P FedinNikolaev Institute of Inorganic Chemistry, Lavrentiev Avenue 3, Novosibirsk, Russian Federation, 630090.

Funding

China Scholarship Council 202210340004China Scholarship Council 202210340005General Fund of the Education Department Project of Liaoning Province LJKZ0315Natural Science Foundation of China U1608224 and 21671138
6 · The paper itself

Abstract

Co-based coordination polymers (CoCP) based on 4,4'-bis(1H-benzo[d]imidazol-1-yl)-1,1'-biphenyl (BMB) ligand have been synthesized for the first time by the solvothermal method. The CoCP was carbonized at 700 °C under a nitrogen atmosphere to obtain carbide coordination polymer (C-CoCP) with a unique two-dimensional layered network structure. C-CoCP@GO was obtained by binding with GO and C-CoCP, its morphology and structure were investigated by XRD, SEM, EDS, FTIR, and TGA, which confirmed its two-dimensional stacked layered structure with high catalytic activity and large specific surface area. A highly sensitive electrochemical sensor was constructed for the simultaneous detection of hydroquinone and catechol based on the prepared carbon-based composite. Under optimized conditions, the working potentials (vs. Ag/AgCl) of HQ and CC are at 0.097 V and 0.213 V, respectively. The sensor exhibited an extremely wide linear range of 3-600 μM and 3-1750 μM for hydroquinone (HQ) and catechol (CC), respectively, with limits of detection (LOD) of 0.46 μM and 0.27 μM. The electrode material demonstrated stability over 14 days without significant attenuation of the response signal. Impressively, the sensor shows high stability, reproducibility, and selectivity due to the stable carbon skeleton structure of the C-CoCP material. In addition, it can be applied to the detection of hydroquinone in real samples with high interference immunity and high recovery. Hence, the C-CoCP@GO composite proved to be a great prospect and highly sensitive sensing platform for the detection of phenolic isomers.

Indexed as

Carbon compositesCoordination polymersCyclic voltammetryDifferential pulse voltammetryElectrochemical sensing;Hydroquinone and catechol interference immunity

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.