A Low-Cost Instrumented Shoe System for Gait Phase Detection Based on Foot Plantar Pressure Data.

Xinyao Hu, Qingsong Duan, Junpeng Tang, Gengshu Chen, Zhong Zhao, Zhenglong Sun, Chao Chen, Xingda Qu

Abstract read
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xinyao HuInstitute of Human Factors and Ergonomics, College of Mechatronics and Control EngineeringShenzhen University Shenzhen 518060 China.ORCID 0000-0002-9187-6440
Qingsong DuanInstitute of Human Factors and Ergonomics, College of Mechatronics and Control EngineeringShenzhen University Shenzhen 518060 China.
Junpeng TangInstitute of Human Factors and Ergonomics, College of Mechatronics and Control EngineeringShenzhen University Shenzhen 518060 China.ORCID 0000-0001-7890-6935
Gengshu ChenInstitute of Human Factors and Ergonomics, College of Mechatronics and Control EngineeringShenzhen University Shenzhen 518060 China.
Zhong ZhaoInstitute of Human Factors and Ergonomics, College of Mechatronics and Control EngineeringShenzhen University Shenzhen 518060 China.ORCID 0000-0001-5236-4568
Zhenglong SunSchool of Science and EngineeringThe Chinese University of Hong Kong Shenzhen 518172 China.ORCID 0000-0002-8135-1659
Chao ChenDepartment of OrthopedicsSchool of Traditional Chinese MedicineSouthern Medical University Guangzhou Guangdong 510515 China.
Xingda QuInstitute of Human Factors and Ergonomics, College of Mechatronics and Control EngineeringShenzhen University Shenzhen 518060 China.ORCID 0000-0003-1764-0357

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents a novel low-cost and fully-portable instrumented shoe system for gait phase detection. The instrumented shoe consists of 174 independent sensing units constructed based on an off-the-shelf force-sensitive film known as the Velostat conductive copolymer. A zero potential method was implemented to address the crosstalk effect among the matrix-formed sensing arrays. A customized algorithm for gait event and phase detection was developed to estimate stance sub-phases including initial contact, flat foot, and push off. Experiments were carried out to evaluate the performance of the proposed instrumented shoe system in gait phase detection for both straight-line walking and turning walking. The results showed that the mean absolute time differences between the estimated phases by the proposed instrumented shoe system and the reference measurement ranged from 45 to 58 ms during straight-line walking and from 51 to 77 ms during turning walking, which were comparable to the state of art.Clinical and Translational Impact Statement-By allowing convenient gait monitoring in home healthcare settings, the proposed system enables extensive ADL data collection and facilitates developing effective treatment and rehabilitation strategies for patients with movement disorders.

Indexed as

FootShoesGaitHumansLower ExtremityWalkingfoot plantar pressureforce-sensitive filmgait phase detectionInstrumented shoe

Identifiers

PMID38089000
PMCPMC10712682

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.