ArticleIEEE journal of translational engineering in health and medicine2024
Non-Contact Measurement of Blood Oxygen Saturation Using Facial Video Without Reference Values.
Article in IEEE journal of translational engineering in health and medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 9 citations in OpenAlex.
- Reliability of contactless vital sign measurement algorithms for use in drone-based mass casualty triage.Scientific reports · 2026Article
- Continuous non-contact vital sign monitoring of neonates in intensive care units using RGB-D cameras.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The continuous measurement of percutaneous oxygen saturation (SpO2) enables diseases that cause hypoxemia to be detected early and patients' conditions to be monitored. Currently, SpO2 is mainly measured using a pulse oximeter, which, owing to its simplicity, can be used in clinical settings and at home. However, the pulse oximeter requires a sensor to be in contact with the skin; therefore, prolonged use of the pulse oximeter for neonates or patients with sensitive skin may cause local inflammation or stress due to restricted movement. In addition, owing to COVID-19, there has been a growing demand for the contactless measurement of SpO2. Several studies on measuring SpO2 without contact used skin video images have been conducted. However, in these studies, the SpO2 values were estimated using a linear regression model or a look-up table that required reference values obtained using a contact-type pulse oximeter. In this study, we propose a new technique for the contactless measurement of SpO2 that does not require reference values. Specifically, we used certain approaches that reduced the influence of non-pulsating components and utilized different light wavelengths of video images that penetrated subcutaneously to different depths. We experimentally investigated the accuracy of SpO2 measurements using the proposed methods. The results indicate that the proposed methods were more accurate than the conventional method.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.