Evidence map›Paper›PMID 38088992›Full record

ArticleIEEE journal of translational engineering in health and medicine2024

Automated, Vision-Based Goniometry and Range of Motion Calculation in Individuals With Suspected Ehlers-Danlos Syndromes/Generalized Hypermobility Spectrum Disorders: A Comparison of Pose-Estimation Libraries to Goniometric Measurements.

Andrea Sabo, Nimish Mittal, Amol Deshpande, Hance Clarke, Babak Taati

Open access · goldAbstract read
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
11.5field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Accuracy of the Automated Range of Motion Observer and Reporter Software for Fully Automated Joint Measurement From Patient Videos.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Andrea SaboKITE Research Institute, Toronto Rehabilitation Institute--University Health Network Toronto ON M5G 2A2 Canada.
Nimish MittalKITE Research Institute, Toronto Rehabilitation Institute--University Health Network Toronto ON M5G 2A2 Canada.
Amol DeshpandeFaculty of MedicineUniversity of Toronto Toronto ON M5S 1A1 Canada.
Hance ClarkeDepartment of Anesthesiology and Pain MedicineUniversity of Toronto Toronto ON M5S 1A1 Canada.
Babak TaatiKITE Research Institute, Toronto Rehabilitation Institute--University Health Network Toronto ON M5G 2A2 Canada.ORCID 0000-0001-9763-4293
University Health Network · CAUniversity of Toronto · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Generalized joint hypermobility (GJH) often leads clinicians to suspect a diagnosis of Ehlers Danlos Syndrome (EDS), but it can be difficult to objectively assess. Video-based goniometry has been proposed to objectively estimate joint range of motion in hyperextended joints. As part of an exam of joint hypermobility at a specialized EDS clinic, a mobile phone was used to record short videos of 97 adults (89 female, 35.0 ± 9.9 years old) undergoing assessment of the elbows, knees, shoulders, ankles, and fifth fingers. Five body keypoint pose-estimation libraries (AlphaPose, Detectron, MediaPipe-Body, MoveNet - Thunder, OpenPose) and two hand keypoint pose-estimation libraries (AlphaPose, MediaPipe-Hands) were used to geometrically calculate the maximum angle of hyperextension or hyperflexion of each joint. A custom domain-specific model with a MobileNet-v2 backbone finetuned on data collected as part of this study was also evaluated for the fifth finger movement. Spearman's correlation was used to analyze the angles calculated from the tracked joint positions, the angles calculated from manually annotated keypoints, and the angles measured using a goniometer. Moderate correlations between the angles estimated using pose-tracked keypoints and the goniometer measurements were identified for the elbow (rho =.722; Detectron), knee (rho =.608; MoveNet - Thunder), shoulder (rho =.632; MoveNet - Thunder), and fifth finger (rho =.786; custom model) movements. The angles estimated from keypoints predicted by open-source libraries at the ankles were not significantly correlated with the goniometer measurements. Manually annotated angles at the elbows, knees, shoulders, and fifth fingers were moderately to strongly correlated to goniometer measurements but were weakly correlated for the ankles. There was not one pose-estimation library which performed best across all joints, so the library of choice must be selected separately for each joint of interest. This work evaluates several pose-estimation models as part of a vision-based system for estimating joint angles in individuals with suspected joint hypermobility. Future applications of the proposed system could facilitate objective assessment and screening of individuals referred to specialized EDS clinics.

Indexed as

Ehlers-Danlos SyndromeElbow JointJoint InstabilityAdultFemaleHumansKnee JointRange of Motion, ArticularGeneralized joint hypermobilityhuman pose-estimationrange of motion estimationvideobased goniometry

Identifiers

PMID38088992
PMCPMC10712662
OpenAlexW4388430235

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.