Evidence map›Paper›PMID 38088990›Full record

ArticleIEEE journal of translational engineering in health and medicine2024

A Novel Navigation Device for Precise Percutaneous Placement of the Guidewire in Femoral Neck Fracture Cannulated Screw Fixation Surgery.

Yutao Cui, Guangkai Ren, Chuangang Peng, Baoming Yuan, Dankai Wu

Open access · goldAbstract readClinical StudyComparative Study
In one paragraph

Article in IEEE journal of translational engineering in health and medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Development and testing of a prognostic scoring system for screw-positioning related femoral neck fracture failures for younger adults.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Yutao CuiOrthopaedic Medical CenterThe Second Hospital of Jilin University Changchun 130041 China.
Guangkai RenOrthopaedic Medical CenterThe Second Hospital of Jilin University Changchun 130041 China.
Chuangang PengOrthopaedic Medical CenterThe Second Hospital of Jilin University Changchun 130041 China.
Baoming YuanOrthopaedic Medical CenterThe Second Hospital of Jilin University Changchun 130041 China.
Dankai WuOrthopaedic Medical CenterThe Second Hospital of Jilin University Changchun 130041 China.ORCID 0000-0001-7859-6631
Second Affiliated Hospital of Jilin University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The accuracy of screw placement is a key factor for the stability of the cannulated screws used in the fixation of femoral neck fractures. In this study we designed a navigation device for ensuring the screw reaches the ideal position for optimal fixation. From March 2019 to September 2020, 66 patients with femoral neck fracture were enrolled and divided into 2 groups, one group was treated using the traditional free-hand cannulated screw fixation and the other using the new navigation device with assisted fixation. The effectiveness of the 2 methods was compared based on surgery duration, intraoperative bleeding, number of fluoroscopic examination and guidewire insertion attempts, screw parallelism, and effective fixation area. Fracture healing, complications and hip joint function were assessed after operation. The new navigation device reduced the duration of surgery without causing additional intraoperative bleeding, and significantly reduced number of fluoroscopy examination and guidewire insertion attempts (4.00±1.58 vs. 6.09±1.94 with traditional surgery). The accuracy of screw implantation was improved, as demonstrated by increased screw parallelism (0.71±0.57° vs. 1.66 ±1.01° with traditional surgery) and higher effective fixed area (64.88±10.52 vs. 58.61±9.19 mm2 with traditional surgery). In the postoperative follow-up, except for one case of femoral head necrosis and one case of bone nonunion in the traditional surgical group, the other patients showed fracture healing. There was no significant difference in hip joint function between the 2 groups. The new navigation device enables rapid and accurate guidewire positioning for cannulated screw fixation through simple operation procedures, resulting in good prospect for clinical transformation.

Indexed as

Femoral Neck FracturesFracture Fixation, InternalBone ScrewsFemur HeadFluoroscopyHumanscannulated screwFemoral neck fracturefracture fixationnavigation device

Identifiers

PMID38088990
PMCPMC10712668
OpenAlexW4388726069

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.