Evidence map›Paper›PMID 38087037›Full record

ArticleScientific reports2023

A feasibility study of robot-assisted percutaneous reduction and fixation technique for treating posterolateral depression tibial plateau fractures.

Yao Lu, YiBo Xu, Cheng Ren, Zhong Li, Kun Zhang, Qiang Huang, Teng Ma

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Yao LuDepartment of Orthopedics, Hong Hui Hospitalospital, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China.
YiBo XuDepartment of Orthopedics, Hong Hui Hospitalospital, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China.
Cheng RenDepartment of Orthopedics, Hong Hui Hospitalospital, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China.
Zhong LiDepartment of Orthopedics, Hong Hui Hospitalospital, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China.
Kun ZhangDepartment of Orthopedics, Hong Hui Hospitalospital, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China.
Qiang HuangDepartment of Orthopedics, Hong Hui Hospitalospital, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China. 369292735@qq.com.
Teng MaDepartment of Orthopedics, Hong Hui Hospitalospital, Xi'an Jiaotong University, Xi'an, 710054, Shaanxi, China. gukemt@163.com.
Xi'an Honghui Hospital · CNXi'an Jiaotong University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Posterolateral (PL)-depression fractures of the tibial plateau are difficult to manage. The aim of this study was: (1) to present our experience with a novel technique of robot-assisted percutaneous reduction and fixation and (2) to compare it with the traditional percutaneous screw osteosynthesis (PSO) technique for the treatment of PL-depression tibial plateau fractures. The clinical data of patients with PL-depression tibial plateau fractures treated by robot-assisted percutaneous reduction and fixation technique and traditional PSO technique from January 2017 to January 2021 were retrospectively analyzed. Among them, there were 18 cases in the robot-assisted group (RA group) and 23 cases in the PSO group. All fractures were unilateral, closed and fresh PL-depression fractures of the tibial plateau. Patients in the RA group were treated by robot assisted reduction and minimally invasive absorbable screw fixation. The PSO group was treated by closed reduction and percutaneous absorbable screw osteosynthesis. The incision length, operation time, intraoperative blood loss, fluoroscopic times, inpatient time, weight training time and postoperative complications of the two groups were statistically analyzed. The Rasmussen radiological score was used to assess the reduction quality after operation while the Rasmussen functional score was used to evaluate knee joint functions at one year postoperatively. All patients were followed for at least one year. There was no significant difference in demographic information between the two groups (p > 0.05). Compared with the PSO group, the RA group showed less fluoroscopic times and better Rasmussen radiological and functional scores (p < 0.05). Besides, there was no significant difference in the incidence of postoperative complications between the two groups (p > 0.05). The novel robot-assisted percutaneous reduction and fixation technique had the characteristics of less radiation, accurate reduction and fixation. It could accelerate the rehabilitation of patients with PL-depression fractures of the tibial plateau and enable patients to obtain good joint functions.

Indexed as

RoboticsTibial FracturesTibial Plateau FracturesDepressionFeasibility StudiesFracture Fixation, InternalHumansPostoperative ComplicationsRetrospective StudiesTreatment Outcome

Identifiers

PMID38087037
PMCPMC10716110
OpenAlexW4389648578

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.