Evidence map›Paper›PMID 38084392›Full record

ArticleMagnetic resonance in medicine2024

Fast high-resolution prospective motion correction for single-voxel spectroscopy.

Isaac M Adanyeguh, Nutandev Bikkamane Jayadev, Pierre-Gilles Henry, Dinesh K Deelchand

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Accelerated Navigator for Rapid ∆BNMR in biomedicine · 2025
    Article
  4. BMagnetic resonance in medicine · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Isaac M AdanyeguhCenter for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA.ORCID 0000-0003-1402-5877
Nutandev Bikkamane JayadevCenter for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA.
Pierre-Gilles HenryCenter for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA.
Dinesh K DeelchandCenter for Magnetic Resonance Research and Department of Radiology, University of Minnesota Medical School, Minneapolis, Minnesota, USA.ORCID 0000-0003-4266-4780

Funding

TRD4 - Ultrahigh Field Engineering and SafetyP41EB027061 · NIBIB · UNIVERSITY OF MINNESOTA · PI Gregory John Metzger, KAMIL UGURBIL · 2019 to 2026
$11.7M
Institutional Center Cores for Advanced NeuroimagingP30NS076408 · NINDS · UNIVERSITY OF MINNESOTA · PI UGURBIL, KAMIL · 2012 to 2020
$4.2M
Computer Aided Diagnostic System for Prostate Cancer Detection Using Quantitative Multiparametric MRIR01CA241159 · NCI · UNIVERSITY OF MINNESOTA · PI METZGER, GREGORY JOHN · 2021 to 2025
$3.0M
Fully Automated Motion-corrected MR Spectroscopy in Human Brain and Spinal CordR01EB030000 · NIBIB · UNIVERSITY OF MINNESOTA · PI DEELCHAND, DINESH KUMAR · 2020 to 2024
$1.3M
High Performance Connectome Upgrade for Human 3T MR ScannerS10OD017974 · OD · UNIVERSITY OF MINNESOTA · PI LIM, KELVIN O. · 2014 to 2014
$600k
NCI NIH HHS R01 CA241159NIBIB NIH HHS P41 EB027061NIBIB NIH HHS R01 EB030000NIH HHS P30 NS076408NIH HHS P41 EB027061NIH HHS R01 EB030000NIH HHS S10 OD017974NIH HHS S10OD017974NINDS NIH HHS P30 NS076408
6 · The paper itself

Abstract

purposeTo develop a fast high-resolution image-based motion correction method using spiral navigators with multislice-to-volume registration.

methodsA semi-LASER sequence was modified to include a multislice spiral navigator for prospective motion correction (∼305 ms including acquisition, processing, and feedback) as well as shim and frequency navigators for prospective shim and frequency correction (∼100 ms for each). MR spectra were obtained in the prefrontal cortex in five healthy subjects at 3 T with and without prospective motion and shim correction. The effect of key navigator parameters (number of slices, image resolution, and excitation flip angle) on registration accuracy was assessed using simulations.

resultsWithout prospective motion and shim correction, spectral quality degraded significantly in the presence of voluntary motion. In contrast, with prospective motion and shim correction, spectral quality was improved (metabolite linewidth = 6.7 ± 0.6 Hz, SNR= 67 ± 9) and in good agreement with baseline data without motion (metabolite linewidth = 6.9 ± 0.9 Hz, SNR = 73 ± 9). In addition, there was no significant difference in metabolites concentrations measured without motion and with prospective motion and shim correction in the presence of motion. Simulations showed that the registration precision was comparable when using three navigator slices with 3 mm resolution and when using the entire volume (all slices) with 8 mm resolution.

conclusionThe proposed motion correction scheme allows fast and precise prospective motion and shim correction for single-voxel spectroscopy at 3 T. With 3 mm resolution, only a few navigator slices are necessary to achieve excellent motion correction performance.

Indexed as

ArtifactsBrainHumansMagnetic Resonance ImagingMotionProspective StudiesSpectrum Analysis3 Timage-based navigatorsmotion correctionprospectivereal timesLASER

Identifiers

PMID38084392
PMCPMC10872424

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.