ArticleSpine surgery and related research2023
Intraoperative Radiation Exposure from O-arm-based 3D Navigation in Spine Surgery.
Article in Spine surgery and related research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 6 citations in OpenAlex.
- Intraoperative mobile CT and virtual-assisted lung mapping for pulmonary nodule localization: workflow characteristics and radiation dosage in a single-center experience.General thoracic and cardiovascular surgery · 2026Article
- Methodological considerations in comparing intraoperative CT and VAL-MAP workflows.General thoracic and cardiovascular surgery · 2026Article
- Accuracy and Safety of Pedicle Screw Insertion Using Novel Intraoperative Computed Tomography Navigation System for Spinal Fusion Surgery.Spine surgery and related research · 2025Article
- The Impact of Navigation in Lumbar Spine Surgery: A Study of Historical Aspects, Current Techniques and Future Directions.Journal of clinical medicine · 2024Review
- A Novel Intraoperative CT Navigation System for Spinal Fusion Surgery in Lumbar Degenerative Disease: Accuracy and Safety of Pedicle Screw Placement.Journal of clinical medicine · 2024Article
- Letter to the Editor concerning "Evaluating accuracy in robotic-assisted thoracolumbar pedicle screw placement: Insights from a single-center study of 410 patients" by A. SoniJournal of craniovertebral junction & spineArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Intraoperative three-dimensional (3D) imaging guide technology, such as the O-arm surgical imaging system, is a beneficial tool in spinal surgery that provides real-time 3D images of a patient's spine. This study aims to determine the exposure dose from intraoperative O-arm imaging. Methods: A consecutive retrospective review of all patients undergoing spinal surgery was conducted between June 2019 and August 2022. Demographic and operative data were collected from electronic medical records. Results: Intraoperative O-arm imaging was conducted in 206 (12.9%) of 1599 patients, ranging from one to 4 scans per patient (1.17±0.43 scans). Single O-arm imaging enabled navigation of seven vertebrae in the cervical spine, seven in the thoracic spine, five in the thoracolumbar spine, and four in the lumbar spine on average. The number of O-arm shots per surgery was 1.15±0.36, 1.06±0.24, 1.61±0.7, and 1.07±0.25 for cervical, thoracic, thoracolumbar, and lumbar spinal cases, respectively. The exposure doses represented by dose length products in single O-arm imaging were 377±19 mGy-cm, 243±22 mGy-cm, 378±38 mGy-cm, and 258±11 mGy-cm for cervical, thoracic, thoracolumbar, and lumbar spine cases, respectively. We observed a weak positive correlation between the number of fused spinal levels and the exposure dose. Conclusions: Intraoperative radiation exposure from O-arm imaging was lower than the national diagnostic reference levels in Japan established based on the International Commission on Radiological Protection publication, demonstrating its safety from the standpoint of radiological protection in most cases. In surgeries with a large range of fixations, such as corrective deformity surgery, the number of imaging sessions and the amount of intraoperative radiation exposure would increase, leading surgeons to pay attention to the risk of radiation in spinal surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials