Evidence map›Paper›PMID 38071854›Full record

ArticleUltrasonics sonochemistry2023

Ultrasound tissue scatterer distribution imaging: An adjunctive diagnostic tool for shear wave elastography in characterizing focal liver lesions.

Chien-Ming Chen, Ya-Chun Tang, Shin-Han Huang, Kuang-Tse Pan, Kar-Wai Lui, Yan-Heng Lai, Po-Hsiang Tsui

Abstract read
In one paragraph

Article in Ultrasonics sonochemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Chien-Ming ChenDepartment of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan.
Ya-Chun TangDepartment of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan; Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan. Electronic address: tyj@cgmh.org.tw.
Shin-Han HuangDepartment of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
Kuang-Tse PanDepartment of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan.
Kar-Wai LuiDepartment of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan.
Yan-Heng LaiDepartment of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan.
Po-Hsiang TsuiDepartment of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan; Division of Pediatric Gastroenterology, Department of Pediatrics, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan; Liver Research Center, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan; Research Center for Radiation Medicine, Chang Gung University, Taoyuan, Taiwan. Electronic address: tsuiph@mail.cgu.edu.tw.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesFocal liver lesion (FLL) is a prevalent finding in cross-sectional imaging, and distinguishing between benign and malignant FLLs is crucial for liver health management. While shear wave elastography (SWE) serves as a conventional quantitative ultrasound tool for evaluating FLLs, ultrasound tissue scatterer distribution imaging (TSI) emerges as a novel technique, employing the Nakagami statistical distribution parameter to estimate backscattered statistics for tissue characterization. In this prospective study, we explored the potential of TSI in characterizing FLLs and evaluated its diagnostic efficacy with that of SWE.

methodsA total of 235 participants (265 FLLs; the study group) were enrolled to undergo abdominal examinations, which included data acquisition from B-mode, SWE, and raw radiofrequency data for TSI construction. The area under the receiver operating characteristic curve (AUROC) was used to evaluate performance. A dataset of 20 patients (20 FLLs; the validation group) was additionally acquired to further evaluate the efficacy of the TSI cutoff value in FLL characterization.

resultsIn the study group, our findings revealed that while SWE achieved a success rate of 49.43 % in FLL measurements, TSI boasted a success rate of 100 %. In cases where SWE was effectively implemented, the AUROCs for characterizing FLLs using SWE and TSI stood at 0.84 and 0.83, respectively. For instances where SWE imaging failed, TSI achieved an AUROC of 0.78. Considering all cases, TSI presented an overall AUROC of 0.81. There was no statistically significant difference in AUROC values between TSI and SWE (p > 0.05). In the validation group, using a TSI cutoff value of 0.67, the AUROC for characterizing FLLs was 0.80.

conclusionsIn conclusion, ultrasound TSI holds promise as a supplementary diagnostic tool to SWE for characterizing FLLs.

Indexed as

Elasticity Imaging TechniquesLiver NeoplasmsDiagnosis, DifferentialHumansProspective StudiesUltrasonographyEnvelope statisticsFocal liver lesionNakagami distributionUltrasound

Identifiers

PMID38071854
PMCPMC10755484

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.