ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2024
Comparative study of mechanical performance of various fixation constructs in multifragmentary distal humeral shaft fracture: a finite element analysis.
Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 3 citations in OpenAlex.
- Biomechanical comparison of the anterior reverse PHILOS and locking compression plate extra-articular distal humerus plates for extra-articular distal humeral fractures.Frontiers in bioengineering and biotechnology · 2025Article
- Management of extra-articular fracture of the distal humerus with the upside-down use of PHILOS plates in front of the humerus: a retrospective study of 20 patients after 28.3 months.BMC musculoskeletal disorders · 2024Article
- Biomechanical assessment and comparison of fixation methods for bilateral sacroiliac joint luxation in 3D-printed feline pelvic bone models.Veterinary world · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThere has been no scientific mechanical assessment demonstrating the optimal fixation technique in multifragmentary fractures of the distal humeral shaft. The purpose of the present study was to compare the biomechanical performance of 5 fixation constructs as used in minimally invasive plating osteosynthesis (MIPO) for distal humeral shaft fractures.
methodsThree-dimensional (3D) humerus model with 20 mm distal humeral shaft fracture gap simulating multifragmentary fracture was created from computed tomography data and virtually fixed by 5 fixation techniques as MIPO, i.e., anterior narrow dynamic compression plate (DCP), anterior narrow locking compression plate (LCP), anterior reversed proximal humeral internal locking system (R-PHILOS), extra-articular distal humerus locking compression plate (LCP-EADH), and anteromedial LCP. All constructs were biomechanically tested under 6 loading conditions by means of finite element analysis, i.e., 250-N axial compression, 7.5-N m internal rotation, 7.5-N m external rotation, 10-N m posterior bending, 10-N m valgus rotation, and 10-N m varus rotation. In addition, A 3D model of each construct was fabricated as 3D printed models. Fixations were applied to the 3D printing model which were later mechanically tested to validate the FE results.
resultsEQV stress exhibited on anterior narrow LCP and anterior R-PHILOS were comparable which were lower than other constructs under axial compression and valgus-varus bending. Anterior R-PHILOS produced lower EQV stress than other constructs under internal-external rotation and posterior bending. On the whole, R-PHILOS demonstrated a comparable fracture displacement to those LCP with anterior or anteromedial approaches, that achieved the lowest displacement values. In addition, the experimental mechanical test values shared a correlation with the FE model results.
conclusionOverall, the anterior R-PHILOS was considered as a potential candidate for multifragmentary distal humeral shaft fractures. It demonstrated efficacious biomechanical performance in terms of implant stress and distal fragment displacement.