ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2024
A novel coupling quality index to estimate the coupling efficiency in Vibrant Soundbridge.
Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Intraoperative ABR in Vibrant Soundbridge Surgery: Influence of Bone-Conduction Thresholds.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026Article
- Early activation of active middle ear implants: a prospective study.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025Article
- Intraoperative ABR measurements via the active middle ear implant vibrant soundbridge using different types of couplers.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025Article
- Vibrant Soundbridge and Porous Polyethylene Auricular Reconstruction in a Single‑Stage Procedure.Science progressArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe objective-based methods for intraoperative monitoring have been suggested to assess the coupling and the outcomes of Vibrant Soundbridge (VSB). Although several techniques were proposed, they have not been widely adopted due to their complexity and invasiveness. PURPOSE: This study aimed to investigate the accuracy of a new coupling quality index using an intraoperative ABR threshold via AcoustiAP and its correlation with the perioperative measures.
methodsThis is a prospective study conducted at a tertiary center. The medical records were retrieved for all patients who underwent VSB implantation and had an intraoperative objective assessment for the coupling efficiency. AcoustiAP was used to evaluate the intraoperative ABR thresholds, which were assessed directly after the floating mass transducer (FMT) placement using acoustic CE-Chirp signals. The Vibrogram was used for the postoperative audiological evaluation. A new coupling quality index was calculated based on the intraoperative ABR thresholds.
resultsTen patients were eligible for the present study. The ABR thresholds for good coupling ranged from 35 to 60 dBnHL. The loose coupling thresholds ranged considerably from 40 to 100 dBnHL. Overall, the median intraoperative ABR threshold at good coupling was 42.5 (40-60) dBnHL and 60 (40-100) dBnHL at loose coupling. The analysis showed that there was a significant change in the coupling quality index at the good and loose coupling points (24.3 ± 14 vs 38.8 ± 18.2, respectively, p < 0.001). At a cut-off value of 22.6 dB, the coupling quality index had a sensitivity of 70% and specificity of 90% for discriminating good and loose coupling.
conclusionThis study provides evidence for the utility of intraoperative ABR measurements in predicting the coupling efficiency in patients with VSB. Our results showed that the coupling quality index had an acceptable accuracy in discriminating between good and poor coupling, which can help clinicians optimize the fitting process for individuals and may ultimately lead to improved patient outcomes.
Indexed as
Identifiers
38070046What OpenQuestion holds