ArticleMaterials (Basel, Switzerland)2023
Design and Structural Factors' Influence on the Fatigue Life of Steel Products with Additive Manufacturing.
Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
Abstract
The influence of implant design and structural factors on fatigue life under cyclic loading was investigated. The implants were manufactured from 316L steel powder using 3D printing for medical use. A simulation model of implant deformation was built using ANSYS software. The obtained data showed that the geometry of the implant had the necessary margin of safety for osseointegration time. It was found that the stress concentration factor, which is associated with fatigue life, for an implant with a hexagon head and internal thread depends on the mechanical properties of the metal, design, and load conditions. The presence of internal threads and holes in the implant increases the stress concentration factor by more than 10 times. The number of load cycles for the failure of the implant, which was calculated by taking into account a coefficient for reducing the endurance limit, was found to be sufficient for implant osseointegration.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.