ArticleSensors (Basel, Switzerland)2023
Design and Experimental Results of a Three-Dimensional Force Sensor for Shearer Cutting Pick Force Monitoring.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 3 citations in OpenAlex.
- Article
- Design of Digital Twin Cutting Experiment System for Shearer.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The main focus of this work is the design and development of a three-dimensional force sensor for the cutting pick of a coal mining shearer's simulated drum. This sensor is capable of simultaneously measuring the magnitude of force along three directions of the cutting pick during the cutting sample process. The three-dimensional force sensor is built based on the strain theory of material mechanics, and reasonable structural design is implemented to improve its sensitivity and reduce inter-axis coupling errors. The strain distribution of the sensor is analyzed using finite element analysis software, and the distribution of the strain gauges is determined based on the analysis results. In addition, a calibration test system is designed for the sensor, and the sensitivity, linearity, and inter-axis coupling errors of the sensor are calibrated and tested using loading experiments in three mutually perpendicular directions. Modal simulation analysis and actual cutting pick testing of the coal mining machine's simulated drum are conducted to study the dynamic characteristics and functionality of the sensor in practical applications. The experimental results depict sensitivities of 0.748 mV/V, 2.367 mV/V, and 2.83 mV/V for the newly developed sensor, respectively. Furthermore, the cross-sensitivity error was lower than 5.02%. These findings validate that the sensor's structure satisfies the measurement requirements for pick-cutting forces.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.