ArticleSensors (Basel, Switzerland)2023
A Flexible Eddy Current TMR Sensor for Monitoring Internal Fatigue Crack.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Analytical Impedance Model of T-II Composite-Core ECT Probe Using Truncated Region Eigenfunction Expansion.Sensors (Basel, Switzerland) · 2026Article
- Modeling of a Novel T-Core Sensor with an Air Gap for Applications in Eddy Current Nondestructive Evaluation.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This paper proposes a flexible eddy current TMR (FEC-TMR) sensor to monitor the internal crack of metal joint structures. First, the finite element model of the FEC-TMR sensor is established to analyze the influence of the sensor's crack identification sensitivity with internal crack propagation at different depths and determine the optimal location and exciting frequency of the sensor. Then, the optimal longitudinal spacing and exciting frequency of the sensor are tested by experiment. The experimental results are consistent with the simulation results, which verify the correctness of the simulation model. Finally, the experiment is carried out for internal cracks of different depths to verify that the sensor can monitor internal cracks, and the crack identification sensitivity gradually decreases with the increase in the depth of the crack from the surface.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials