Evidence map›Paper›PMID 38067829›Full record

ArticleSensors (Basel, Switzerland)2023

A Flexible PDMS-Based Optical Biosensor for Stretch Monitoring in Cardiac Tissue Samples.

Andrea Sannino, Antonio Velarte, Aránzazu Otín, José Ignacio Artigas, Aida Oliván-Viguera

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Andrea SanninoGroup of Power Electronics and Microelectronics, Aragon Institute for Engineering Research, University of Zaragoza, 50018 Zaragoza, Spain.ORCID 0000-0001-9710-0910
Antonio VelarteBiomedical Signal Interpretation and Computational Simulation Group, Aragon Institute for Engineering Research, Aragon Health Research Institute, University of Zaragoza, 50018 Zaragoza, Spain.ORCID 0000-0003-4361-6676
Aránzazu OtínGroup of Power Electronics and Microelectronics, Aragon Institute for Engineering Research, University of Zaragoza, 50018 Zaragoza, Spain.ORCID 0000-0003-1403-1505
José Ignacio ArtigasGroup of Power Electronics and Microelectronics, Aragon Institute for Engineering Research, University of Zaragoza, 50018 Zaragoza, Spain.ORCID 0000-0002-8007-5613
Aida Oliván-VigueraCIBER-BBN, Biomedical Signal Interpretation and Computational Simulation Group, Aragon Institute for Engineering Research, Aragon Health Research Institute, University of Zaragoza, 50018 Zaragoza, Spain.ORCID 0000-0001-5348-924X
Universidad de Zaragoza · ES

Funding

European Research Council 638284
6 · The paper itself

Abstract

Cardiotoxicity, characterized by adverse impacts on normal heart function due to drug exposure, is a significant concern due to the potentially serious side effects associated with various pharmaceuticals. It is essential to detect the cardiotoxicity of a drug as early as possible in the testing phase of a medical composite. Therefore, there is a pressing need for more reliable in vitro models that accurately mimic the in vivo conditions of cardiac biopsies. In a functional beating heart, cardiac muscle cells are under the effect of static and cyclic stretches. It has been demonstrated that cultured cardiac biopsies can benefit from external mechanical loads that resemble the in vivo condition, increasing the probability of cardiotoxicity detection in the early testing stages. In this work, a biosensor is designed and fabricated to allow for stretch monitoring in biopsies and tissue cultures using an innovative sensing mechanism. The detection setup is based on a biocompatible, thin, flexible membrane-where the samples are attached-which is used as an optical waveguide to detect pressure-caused shape changes and stretches. Various prototypes have been fabricated with a cost-effective process, and different measurements have been carried out to experimentally validate the proposed measurement technique. From these evaluations, stretches of up to 1.5% have been measured, but the performed simulations point towards the possibility of expanding the considered technique up to 10-30% stretches.

Indexed as

CardiotoxicityHeartHumansbiomimetic culture chamberbiosensorcardiac applicationsoptical fiberorgan-on-chipPDMSstrain sensor

Identifiers

PMID38067829
PMCPMC10708643
OpenAlexW4389086097

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.