Evidence map›Paper›PMID 38067781›Full record

ArticleSensors (Basel, Switzerland)2023

Research on the Design and Alignment Method of the Optic-Mechanical System of an Ultra-Compact Fully Freeform Space Camera.

Yunfeng Li, Zongxuan Li, Tiancong Wang, Shuping Tao, Defu Zhang, Shuhui Ren, Bin Ma, Changhao Zhang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yunfeng LiChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Zongxuan LiChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.ORCID 0000-0001-5239-6789
Tiancong WangChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Shuping TaoChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Defu ZhangChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Shuhui RenChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Bin MaChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Changhao ZhangChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.ORCID 0000-0001-5365-9456

Funding

Youth Innovation Promotion Association 2021218
6 · The paper itself

Abstract

As space resources become increasingly constrained, the major space-faring nations are establishing large space target monitoring systems. There is a demand for both the number and the detection capability of space-based optical monitoring equipment. The detection range (i.e., field of view) and parasitic capability (lightweight and small size) of a single optical payload will largely reduce the scale and cost of the monitoring system. Therefore, in this paper, the optic-mechanical system of an ultra-lightweight and ultra-compact space camera and the optical alignment method are investigated around a fully freeform off-axis triple-reversal large field of view (FOV) optical system. The optic-mechanical system optimisation design is completed by adopting the optic-mechanical integration analysis method, and the weight of the whole camera is less than 10 kg. In addition, to address the mounting problems caused by the special characteristics of the freeform surface optical system, a dual CGH coreference alignment method is innovatively proposed. The feasibility of the method is verified by the mounting and testing test, and the test results show that the system wavefront difference is better than 1/10 λ. The imaging test of the space camera and the magnitude test results meet the design requirements of the optical system. The optic-mechanical system design method and alignment method proposed in this paper are instructive for the design and engineering of large field of view full freeform optical loads.

Indexed as

freeform optical systemsintegrated optomechanical analysisspace optical camera

Identifiers

PMID38067781
PMCPMC10708801

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.