ArticleSensors (Basel, Switzerland)2023
Research on the Design and Alignment Method of the Optic-Mechanical System of an Ultra-Compact Fully Freeform Space Camera.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Design and Analysis of Optical-Mechanical-Thermal Systems for a High-Resolution Space Camera.Sensors (Basel, Switzerland) · 2025Article
- Design Method of Freeform Surface Optical Systems with Low Coupling Position Error Sensitivity.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
As space resources become increasingly constrained, the major space-faring nations are establishing large space target monitoring systems. There is a demand for both the number and the detection capability of space-based optical monitoring equipment. The detection range (i.e., field of view) and parasitic capability (lightweight and small size) of a single optical payload will largely reduce the scale and cost of the monitoring system. Therefore, in this paper, the optic-mechanical system of an ultra-lightweight and ultra-compact space camera and the optical alignment method are investigated around a fully freeform off-axis triple-reversal large field of view (FOV) optical system. The optic-mechanical system optimisation design is completed by adopting the optic-mechanical integration analysis method, and the weight of the whole camera is less than 10 kg. In addition, to address the mounting problems caused by the special characteristics of the freeform surface optical system, a dual CGH coreference alignment method is innovatively proposed. The feasibility of the method is verified by the mounting and testing test, and the test results show that the system wavefront difference is better than 1/10 λ. The imaging test of the space camera and the magnitude test results meet the design requirements of the optical system. The optic-mechanical system design method and alignment method proposed in this paper are instructive for the design and engineering of large field of view full freeform optical loads.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.