Evidence map›Paper›PMID 38067755›Full record

ArticleSensors (Basel, Switzerland)2023

BCG Signal Quality Assessment Based on Time-Series Imaging Methods.

Sungtae Shin, Soonyoung Choi, Chaeyoung Kim, Azin Sadat Mousavi, Jin-Oh Hahn, Sehoon Jeong, Hyundoo Jeong

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sungtae ShinDepartment of Mechanical Engineering, Dong-A University, Busan 49315, Republic of Korea.ORCID 0000-0002-9054-5666
Soonyoung ChoiDepartment of Mechanical Engineering, Dong-A University, Busan 49315, Republic of Korea.
Chaeyoung KimInstitute for Digital Antiaging and Healthcare, Inje University, Gimhae 50834, Republic of Korea.
Azin Sadat MousaviDepartment of Mechanical Engineering, University of Maryland, College Park, MD 20742, USA.ORCID 0000-0002-2886-5642
Jin-Oh HahnDepartment of Mechanical Engineering, University of Maryland, College Park, MD 20742, USA.ORCID 0000-0001-5429-2836
Sehoon JeongInstitute for Digital Antiaging and Healthcare, Inje University, Gimhae 50834, Republic of Korea.
Hyundoo JeongDepartment of Mechatronics Engineering, Incheon National University, Incheon 22012, Republic of Korea.

Funding

National Research Foundation of Korea 2020R1G1A1100421National Research Foundation of Korea RS-2023-00222406U. S. Office of Naval Research N00014-21-1-2031U.S. Office of Naval Research N00014-23-1-2828
6 · The paper itself

Abstract

This paper describes a signal quality classification method for arm ballistocardiogram (BCG), which has the potential for non-invasive and continuous blood pressure measurement. An advantage of the BCG signal for wearable devices is that it can easily be measured using accelerometers. However, the BCG signal is also susceptible to noise caused by motion artifacts. This distortion leads to errors in blood pressure estimation, thereby lowering the performance of blood pressure measurement based on BCG. In this study, to prevent such performance degradation, a binary classification model was created to distinguish between high-quality versus low-quality BCG signals. To estimate the most accurate model, four time-series imaging methods (recurrence plot, the Gramain angular summation field, the Gramain angular difference field, and the Markov transition field) were studied to convert the temporal BCG signal associated with each heartbeat into a 448 × 448 pixel image, and the image was classified using CNN models such as ResNet, SqueezeNet, DenseNet, and LeNet. A total of 9626 BCG beats were used for training, validation, and testing. The experimental results showed that the ResNet and SqueezeNet models with the Gramain angular difference field method achieved a binary classification accuracy of up to 87.5%.

Indexed as

AlgorithmsBallistocardiographyArtifactsHeart RateMotionballistocardiogramclassificationconvolutional neural networksignal quality assessmenttime-series imaging

Identifiers

PMID38067755
PMCPMC10708708

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.