Evidence map›Paper›PMID 38067680›Full record

ArticleSensors (Basel, Switzerland)2023

The Practical Application of Bio-Inspired PMA for the Detection of Partial Discharges in High Voltage Equipment.

Josiel Cruz, Alexandre Serres, Raimundo Freire, Edson Costa, George Xavier, Adriano Oliveira, Vladimir Souza, Pavlos Lazaridis

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 64% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Josiel CruzPost-Graduate Program in Electrical Engineering (PPgEE), Coordination of Postgraduate Studies in Electrical Engineering, Federal University of Campina Grande (UFCG), Campina Grande 58429-900, Brazil.
Alexandre SerresElectrical Engineering Department, Federal University of Campina Grande (UFCG), Campina Grande 58429-900, Brazil.
Raimundo FreireElectrical Engineering Department, Federal University of Campina Grande (UFCG), Campina Grande 58429-900, Brazil.ORCID 0000-0002-5395-7143
Edson CostaElectrical Engineering Department, Federal University of Campina Grande (UFCG), Campina Grande 58429-900, Brazil.ORCID 0000-0003-2998-2039
George XavierElectrical Engineering Department, Federal University of Sergipe (UFS), Sergipe 49100-000, Brazil.
Adriano OliveiraElectrical Engineering Department, Federal Rural University of the Semi-Arid (UFERSA), Mossoró 59625-900, Brazil.ORCID 0000-0002-8739-0675
Vladimir SouzaElectrical Engineering Department, Federal Rural University of the Semi-Arid (UFERSA), Mossoró 59625-900, Brazil.
Pavlos LazaridisSchool of Computing and Engineering, University of Huddersfield, Huddersfield HD1 3DH, UK.ORCID 0000-0001-5091-2567
Universidade Federal de Campina Grande · BRUniversidade Federal Rural do Semi-Árido · BRUniversidade Federal de Sergipe · BRUniversity of Huddersfield · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this paper, the practical application of a bio-inspired antenna for partial discharge (PD) detection in high voltage equipment was evaluated in order to validate the efficiency of using this technology for PD monitoring purposes. For this, PD measurements using the bio-inspired antenna were performed on operational 69 kV potential transformers (PT) in a real substation. After the field experiment, laboratory measurements using the IEC 60270 standard method and a bio-inspired antenna were performed, simultaneously, over the evaluated PT. The results obtained at the substation indicated suspicious frequencies of partial discharge activity in two out of three evaluated potential transformers, mainly for the frequencies of 461 MHz, 1366 MHz, 1550 MHz and 1960 MHz. During the laboratory tests, the presence of partial discharge activity over the suspicious potential transformers was confirmed with the detection of PD apparent charge levels above 20 pC. Finally, the frequency spectrum obtained from the PD signals detected by the bio-inspired antenna in the laboratory presented similar frequency values to those obtained during the practical application at the substation, making it a promising indicator for future defect classification studies using artificial intelligence.

Indexed as

artificial intelligencebio-inspired designmonitoringpartial dischargesUHF sensors

Identifiers

PMID38067680
PMCPMC10708639
OpenAlexW4388859742

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.