Evidence map›Paper›PMID 38066739›Full record

ArticleDiagnostics (Basel, Switzerland)2023

Validation of a New Measuring Instrument for the Assessment of Bite Force.

Ina Nitschke, Celine Moede, Werner Hopfenmüller, Bernhard A J Sobotta, Andreas Koenig, Julia Jockusch

Registry-linked trialAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07007572 (Evaluation Of Marginal Bone Height Changes And Biting Force In Screw Retained Implant Prostheses Using Reinforced Resin Vs Monolithic Zirconium Used In Unilateral Distal Extension Cases), which is not on this map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07007572 phase2recruitingnot on this mapstarted 2024, after this paper: background citation

Evaluation Of Marginal Bone Height Changes And Biting Force In Screw Retained Implant Prostheses Using Reinforced Resin Vs Monolithic Zirconium Used In Unilateral Distal Extension Cases

TypeinterventionalSponsorCairo UniversityRan2024 to 2026Enrolled14ConditionsBiting Forces, Bone, Change, Diabetic (Manifestation), Color StabilityArmsDigitally-fabricated implant supported supra-structure fabricated from reinforced resin, Digitally-fabricated implant supported supra-structure fabricated from monolithic zirconia
3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ina NitschkeGerodontology Section, Department of Prosthetic Dentistry and Materials Science, Leipzig University, Liebigstraße 12, 04103 Leipzig, Germany.ORCID 0000-0001-7262-3838
Celine MoedeGerodontology Section, Department of Prosthetic Dentistry and Materials Science, Leipzig University, Liebigstraße 12, 04103 Leipzig, Germany.ORCID 0009-0007-8406-7251
Werner HopfenmüllerInstitute of Biometry and Clinical Epidemiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, 10117 Berlin, Germany.
Bernhard A J SobottaGerodontology Section, Department of Prosthetic Dentistry and Materials Science, Leipzig University, Liebigstraße 12, 04103 Leipzig, Germany.
Andreas KoenigMaterials Science Section, Department of Prosthetic Dentistry and Materials Science, Leipzig University, Liebigstraße 12, 04103 Leipzig, Germany.
Julia JockuschGerodontology Section, Department of Prosthetic Dentistry and Materials Science, Leipzig University, Liebigstraße 12, 04103 Leipzig, Germany.ORCID 0000-0001-8293-9297

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundthis study aims to validate two occlusal-force-measuring devices by comparing them to a universal testing machine and assessing their reliability across various dental and prosthetic groups. The research comprised two parts: part 1 assessed the measurement accuracy of the Occlusal Force Meter GM 10

resultsboth devices become more accurate and reliable compared to the ZWICK over time of usage. Additionally, higher deviation from the ZWICK can be observed for higher values of forces applied and vice versa for both devices. The PRO's intraoral alignment influences its mean values compared to the OFM in different dental and prosthetic groups.

conclusionboth devices had limitations and required quadratic function calibration, making them suitable only for progression measurements. The study concludes that both the OFM and PRO devices can measure occlusal forces with improved accuracy over time. Intraoral alignment should be considered. Their easy-to-use clinical application would allow a more widespread use of masticatory function diagnosis, which could indicate the need for treatment and improve treatment planning.

Indexed as

chewing functionmeasurement accuracymeasuring deviceocclusal forceprototype

Identifiers

PMID38066739
PMCPMC10705987

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.